Appendix II
EM15 User’s Manual
154
Code
Parameter Name
Functional description
Default
Property
U0-26 Present running time
-
-
●
U0-28
Communication setting
value
-100.00%~100.00%
-
●
U0-29 Encoder feedback speed
-3000.0Hz~3000.0 Hz
-300.00Hz~300.00 Hz
-
●
U0-30 Main frequency X
0.00Hz~300.00 Hz
0.0Hz~3000.0 Hz
-
●
U0-31 Auxiliary frequency Y
0.00Hz~300.00 Hz
0.0Hz~3000.0 Hz
-
●
U0-32
Viewing any register
address value
0°C~200°C
-
●
U0-34 Motor temperature
0°C~200°C
-
●
U0-35 Target torque
-200.0%~200.0%
-
●
U0-36 Resolver position
0~4095
-
●
U0-37 Power factor angle
-
-
●
U0-38 ABZ position
0~65535
-
●
U0-39
Target voltage of V/F
separation
0 V ~ rated motor voltage
-
●
U0-40
Output voltage of V/F
separation
0 V ~ rated motor voltage
-
●
U0-41
DI input state visual
display
-
-
●
U0-42
DO output state visual
display
-
-
●
U0-43
DI function state visual
display 1
-
-
●
U0-44
DO function state visual
display 2
-
-
●
U0-45 Fault information
-
-
●
U0-58 Phase Z signal counting
-
-
●
U0-59
Present setting frequency
(%)
-100.00%~100.00%
-
●
U0-60
Present running frequency
(%)
-100.00%~100.00%
-
●
U0-61
Frequency inverter
running state
0~65535
-
●
U0-62
Current fault code
0~99
-
●
U0-63
Sent value of point-point
communication
-100.00%~100.00%
-
●
U0-64
Number of slaves
0~63
-
●
U0-65 Torque upper limit
-200.00%~ 200.00%
-
●
Group A0: System Parameters
A0-00 User password
0~65535
0
☆
A0-01 Product number
Frequency inverter product number
Model
dependent
●
A0-02 Software version
Software version of control board
Model
dependent
●
A0-06
Function parameters
00: Not display
01
☆