PACMotion™ PSD Installation and User Manual
Section 5
GFK-3168A
September 2020
Mechanical Installation
78
5.11.3.1
IC830DP003 to 024, regen connector X3
Drive Model
Ampere
rating@230V
Ampere
rating@480V
UL region
example:
CE Region example
(Siba):
IC830DP003 to 012
10 A
40 A
FW-xxA14F
110 V to 400 V:
gRL(gS)
400 V to 480 V: aR
IC830DP024
15 A
50 A
IC830DP00306 to IC830DP00606 (X3)
Pin
Signal
Description
1
-RB
External Regen Resistor negative
3
+RB
External Regen Resistor positive
IC830DP01206 (X3)
Pin
Signal
Description
1
+Rbint
Internal Regen Resistor positive
2
-RB
External Regen Resistor negative
4
+RB
External Regen Resistor positive
IC830DP02406 &
IC830DP00307 to IC830DP02407 (X3)
Pin
Signal
Description
2
-RB
External Regen Resistor negative
4
+RB
External Regen Resistor positive