PACMotion™ PSD Installation and User Manual
Section 6
GFK-3168A
September 2020
Setup
106
Code
Message/Warning
F521, n521
Regen over power.
F523
Bus over voltage FPGA
F524, n524
Drive foldback.
F525
Output over current.
F526
Current sensor short circuit.
F527
Iu current AD converter stuck.
F528
Iv current AD converter stuck.
F529
Iu current offset limit exceeded.
F530
Iv current offset limit exceeded.
F531
Power stage fault.
F532
Drive motor parameters setup incomplete.
F534
Failed to read motor parameters from feedback device.
F535
Power-board over-temperature fail.
F541, n541
AC input phase 1 missing.
F542, n542
AC input phase 2 missing.
F543, n543
AC input phase 3 missing.
F560
Regen near capacity, could not prevent over voltage.
F570, n570
Mains phase loss.
n580
Using derivate of position with sensorless feedback type in position mode.
n581
Zero velocity with induction sensorless feedback type in position mode.
n582
Velocity has been limited, commutation frequency max. 599 Hz to meet
ECCN-3A225 / AL-3A225 limits.
F587
Loss of all AC input phases.
n601
Modbus data rate is too high.
F602
Safe torque off.
n603
OPMODE incompatible with CMDSOURCE
n604
EMUEMODE incompatible with DRV.HANDWHEELSRC.
F621
Control Board CRC fault.
F623
Power Board CRC fault.
F624
Power Board Watchdog fault.
F625
Power Board Communication fault.
F626
Power Board FPGA not configured.
F627
Control Board Watchdog fault.
F630
FPGA cyclic read fault.
F631
Issue command timed out.
F701
Fieldbus runtime.
F702, n702
Fieldbus communication lost.
F703
Emergency timeout occurred while axis should disable.
F706, n706
Fieldbus cyclic setpoints missing.