PACMotion™ PSD Installation and User Manual
Section 5
GFK-3168A
September 2020
Mechanical Installation
77
5.11.2
DC Bus topology with busbar
This wiring does not require Y connectors. If a device fails due to a short-circuit, only its DC Bus
fuses (
# 39). are tripped and the rest of the network continues uninterrupted. The solid busbars
can conduct significantly larger currents, because the compensating current does not flow through
the connector as above. For this reason, almost as many drives as desired can be connected in
parallel in this form.
Figure 38: DC Bus Topology with Busbar
5.11.3
External regen resistor (X3)
For technical data on the brake circuit (
Figure 39: External Regen Resistor (X3)