PACMotion™ PSD Installation and User Manual
Section 4
GFK-3168A
September 2020
Technical Description and Data
24
Type
Rated data
Units
120 V / 240 V
Peak regen power, internal resistor
(0.5s)
kW
22
External regen resistor
Ohm
15
Maximum continuous regen power,
external resistor
kW
6
Peak regen power, external resistor (1s)
kW
11.8
Absorption energy in capacitors (+/-
20%)
Ws
180 / 60
DC Bus Capacitance
µF
2720
* depends on connected regen resistor power
4.14.4
Technical data for IC830DPzzz07
Technical data for the regen circuit depends on the drive type and the mains voltage. Supply
voltages, capacitances, and switch-on voltages are all nominal values.
Brake circuit
Supply voltage
Type
Rated data
Units
240 V
400 V / 480 V
IC830DPz
zz07
all types
Switch-on threshold of regen circuit
V
380
760
Overvoltage limit
V
420
840
Maximum regen duty cycle
%
15*
Type
Rated data
Units 240 V
400 V / 480 V
IC830DP00307
Internal regen resistor
Ohm 33
Continuous power, internal resistor
W
80
Peak regen power, internal resistor
(0.5s)
kW
5.5
22.1
External regen resistor
Ohm 33
Continuous regen power, external
resistor
kW
0.77
1.5
Peak regen power, external (1s)
kW
5,4
21.4
Absorption energy in capacitors (+/-
20%)
Ws
5
35 / 20
DC Bus Capacitance
µF
235
IC830DP00607
Internal regen resistor
Ohm 33
Continuous power, internal resistor
W
100
Peak regen power, internal resistor
(0.5s)
kW
5.4
21.4
External regen resistor
Ohm 33
Continuous regen power, external
resistor
kW
1.5
3
Peak regen power, external resistor
(1s)
kW
5.4
21.4
Absorption energy in capacitors (+/-
20%)
Ws
5
35 / 20
DC Bus Capacitance
µF
235
IC830DP01207
Internal regen resistor
Ohm 33
Continuous power, internal resistor
W
100
Peak regen power, internal resistor
(0.5s)
kW
5.4
21.4
External regen resistor
Ohm 33