16
Electrical data
Units
IC830D
P00307
IC830D
P00607
IC830D
P01207
IC830D
P02407
Permitted switch on/off
frequency, mains
1/h
30
Max. inrush current
(@480V, 20°C)
A
9
9
9
9
Rated DC bus link voltage
(Bus Turn on Delay 3ph 1
sec)
V=
340 to 680
Continuous output current ( ± 3%) @ 40°C surrounding air temperature
at 240 V
Arms
3
6
12
24
at 400 V
Arms
3
6
12
24
at 480 V
Arms
3
6
12
24
Peak output current (for 5
s, ± 3%)
Arms
9
18
30
48
Continuous output power @ rated input current
at 3x240 V
kVA
0.6
1.25
2.5
5
at 3x400 V
kVA
1
2
4.2
8.3
at 3x480 V
kVA
1.2
2.5
5
10
Peak output power (for 1 s)
at 3x240 V
kVA
1.8
3.75
6.25
10
at 3x400 V
kVA
3
6.75
10.4
16.7
at 3x480 V
kVA
3.6
7.5
12.5
20
Technical data for regen
circuit
—
Motor inductance min.
at 240 V
mH
3.2
1.6
1.3
0.6
at 400 V
mH
5.3
2.6
2.1
1
at 480 V
mH
6.3
3.2
2.5
1.2
Motor inductance max.
mH
600
300
250
120
Thermal dissipation,
output stage disable
W
max. 20
max. 20
max. 20
max. 25
Thermal dissipation at
rated current
W
102
129
153
237
Noise emission (low
speed/high speed fan)
dB(A)
34/43
34/43
44/52
48/58
Aux. voltage supply (PELV) V=
24 V (±10%, check voltage drop)
-current B, P, T types
without/with motor brake
A=
1 / 2.5
1 / 2.5
1 / 2.5
2 / 4
-current M type
without/with motor brake
A=
1.3 / 2.8
1.3 / 2.8
1.3 / 2.8
2.3 / 4.3
* = motor holding brake is supplied with separated 24 V ±10% auxiliary voltage (
➜