PACMotion™ PSD Installation and User Manual
Section 5
GFK-3168A
September 2020
Mechanical Installation
71
5.10.3
24 V auxiliary supply (X1)
The following diagram describes external 24 VDC power supply, electrically isolated, for example,
via an isolating transformer. The required current rating depends on the use of motor brake card
(
Figure 33: 24V Auxiliary Supply
5.10.3.1
IC830DP003 to 024, connector X1
Pin
Signal
Description
1
+24
+24 VDC Auxiliary voltage
2
GND
24V Supply GND
3
STO
STO enable (Safe Torque Off)