![Emerson PACMotion Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/emerson/pacmotion/pacmotion_installation-and-user-manual_104243034.webp)
PACMotion™ PSD
Installation and User Manual
Section 4
GFK-3168A
September 2020
Technical Description and Data
27
4.14.8
Switch-off behavior
Note:
The drive’s 24
V supply must remain constant. Hardware Enable input disables the power
stage immediately. Configured Digital Inputs and fieldbus commands can be used to perform
controlled stops.
4.14.8.1
Switch-off behavior using the DRV.DIS command
The enable/disable button in Workbench issues a
drv.dis
command internally to the drive. See
Workbench Online Help
for configuring inputs and software commands. Sometimes this enable
signal is called "Software Enable" (SW-Enable).
DRV.DISMODE
DRV.DISMODE controls the behavior of the
drv.dis
command issued
through Workbench, or terminal, or fieldbus. Consult the
Workbench
Online Help
for configuring.
0
Disable axis immediately, if velocity drops below threshold
CS.VTHRESH
or timeout occurs brake is applied. Category 0 stop
according to IEC 60204 (
2
Use controlled stop to disable drive, if velocity drops below threshold
CS.VTHRESH
or timeout occurs brake is applied. Category 1 stop
according to IEC 60204 (