PACMotion™ PSD Installation and User Manual
Section 4
GFK-3168A
September 2020
Technical Description and Data
13
4.2
Ambient Conditions, Ventilation, and Mounting
Position
Storage / Transport
Surrounding air tem-
perature in operation
non UL/cUL regions:
0 to +40 °C under rated conditions
+40 to +55 °C with continuous current derating 4 % per Kelvin
UL/cUL regions: refer to UL approval (
Humidity in operation
Relative humidity 5 to 85%, no condensation, class 3K3
Site altitude
Up to 1000 meters above mean sea level without restriction
1,000 to max. 2,500 meters above mean sea level with power
derating 1.5%/100 m
Pollution level
Pollution level 2 as per IEC 60664-1
Vibrations
Class 3M1 according to IEC 60721-3-3
Enclosure protection
IP 20 according to IEC 60529
Mounting position
Vertical (
Ventilation
Built-in fan (except IC830DP00306 type)
Note: The drive shuts down (fault F234, motor has no torque) in
case of excessively high temperature in the control cabinet.
Make sure sufficient forced ventilation is supplied within the
control cabinet.
4.3
Mechanical Data
Mechanical data
Units
IC830DP00306
IC830DP00606
IC830DP01206
IC830DP02406
Weight (standard width)
kg
1.1
2
3.7
Weight (extended width)
kg
1.3
2.2
4
Height, without
connectors
mm
168
196
248
Height, with connectors
mm
200
225
280
Standard Width
front/back
mm
54/59
72/78.4
96/100
Extended Width
front/back
mm
84/89
91/96
96/100
Depth, without
connectors
mm
156
187
228
Depth, with connectors
mm
185
< 215
<265
Weight (standard width)
kg
2.7
5.3
11.5
Weight (extended width)
kg
2.9
5.5
11.7
Height, without
connectors
mm
256
306
385
Height, with connectors
mm
290
340
526
Standard Width
front/back
mm
65/70
99/105
185/185
Extended Width
front/back
mm
95/100
99/105
-
Depth, without
connectors
mm
185
228
225
Depth, with connectors
mm
<225
<265
<265