Transmitter default values and ranges
(continued)
Table E-1:
Type
Parameter
Default
Range
Comments
Fault action
Downscale
AO fault level – downscale
2.0 mA
1.0 – 3.6 mA
AO fault level – upscale
22 mA
21.0 – 24.0 mA
Last measured value timeout
0.00 sec
LRV
Mass flow rate
−
200.000 g/s
Volume flow rate
−
0.200 l/s
Density
0.000 g/cm
3
Temperature
−
240.000 °C
Drive gain
0.000%
Gas standard volume flow rate
−
423.78SCFM
External temperature
−
240.000 °C
External pressure
0.000 psi
URV
Mass flow rate
200.000 g/s
Volume flow rate
0.200 l/s
Density
10.000 g/cm
3
Temperature
450.000 °C
Drive gain
100.000%
Gas standard volume flow rate
423.78SCFM
External temperature
450.000 °C
External pressure
100.000 psi
Frequency out-
put
Tertiary variable
Mass flow
Frequency factor
1,000.00 Hz
0.001 – 10,000
Hz
Flow rate factor
1000 kg/min
Frequency pulse width
277.0 ms
0 or 0.5 –
277.5 ms
Scaling method
Freq=Flow
Frequency fault action
Downscale
Frequency fault level – upscale
15,000 Hz
10.0 – 15,000
Hz
Frequency output polarity
Active high
Last measured value timeout
0.0 seconds
0.0 – 60.0 sec
Discrete out-
put
Source
Flow direction
Fault Indicator
None
Power
Internal
Polarity
Active high
Default values and ranges
344
Micro Motion
®
Model 2700 Transmitters with Analog Outputs
Содержание MICRO MOTION 2700
Страница 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 142: ...Integrate the meter with the control system 134 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 154: ...Set up the Weights Measures application 146 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 156: ...Operations maintenance and troubleshooting 148 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 327: ...Device Tools Trending Figure C 24 Using ProLink III with the transmitter Configuration and Use Manual 319 ...
Страница 328: ...Using ProLink III with the transmitter 320 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 373: ......