The ON signal may be the high voltage or
0.0 V
, depending on
Frequency Output Polarity
.
Interaction of Frequency Output Maximum Pulse Width and Frequency
Output Polarity
Table 6-7:
Polarity
Pulse width
Active High
Active Low
Procedure
Set
Frequency Output Maximum Pulse Width
as desired.
The default value is 277 milliseconds. You can set
Frequency Output Maximum Pulse Width
to
0 milliseconds or to a value between 0.5 milliseconds and 277.5 milliseconds. The
transmitter automatically adjusts the value to the nearest valid value.
Tip
Micro Motion recommends leaving
Frequency Output Maximum Pulse Width
at the default value. Contact
Micro Motion customer service before changing
Frequency Output Maximum Pulse Width
.
6.3.5
Configure Frequency Output Fault Action and Frequency
Output Fault Level
Display
Not available
ProLink II
•
ProLink
>
Configuration
>
Frequency/Discrete Output
>
Frequency
>
Freq Fault Action
•
ProLink
>
Configuration
>
Frequency/Discrete Output
>
Frequency
>
Freq Fault Level
ProLink III
Device Tools
>
Configuration
>
Fault Processing
Field Communicator
•
Configure
>
Manual Setup
>
Inputs/Outputs
>
Frequency Output
>
FO Fault Parameters
>
FO
Fault Action
•
Configure
>
Manual Setup
>
Inputs/Outputs
>
Frequency Output
>
FO Fault Parameters
>
FO
Fault Level
Overview
Frequency Output Fault Action
controls the behavior of the frequency output if the transmitter
encounters an internal fault condition.
Integrate the meter with the control system
Configuration and Use Manual
113
Содержание MICRO MOTION 2700
Страница 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 142: ...Integrate the meter with the control system 134 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 154: ...Set up the Weights Measures application 146 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 156: ...Operations maintenance and troubleshooting 148 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 327: ...Device Tools Trending Figure C 24 Using ProLink III with the transmitter Configuration and Use Manual 319 ...
Страница 328: ...Using ProLink III with the transmitter 320 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 373: ......