Display codes for process variables
(continued)
Table A-2:
Code
Definition
Comment or reference
FVZ
Field verification zero
Weights & Measures application only
GSV F
Gas standard volume flow
GSV I
Gas standard volume inventory
GSV T
Gas standard volume total
LPO_A
Left pickoff amplitude
LVOLI
Volume inventory
LZERO
Live zero flow
MASSI
Mass inventory
MTR_T
Case temperature (T-Series sensors only)
NET M
Net mass flow rate
Concentration measurement applica-
tion only
NET V
Net volume flow rate
Concentration measurement applica-
tion only
NETMI
Net mass inventory
Concentration measurement applica-
tion only
NETVI
Net volume inventory
Concentration measurement applica-
tion only
PWRIN
Input voltage
Refers to power input to the core pro-
cessor
RDENS
Density at reference temperature
Concentration measurement applica-
tion only
RPO_A
Right pickoff amplitude
SGU
Specific gravity units
STD V
Standard volume flow rate
Concentration measurement applica-
tion only
STDVI
Standard volume inventory
Concentration measurement applica-
tion only
TCDENS
Temperature-corrected density
Petroleum measurement application
only
TCORI
Temperature-corrected inventory
Petroleum measurement application
only
TCORR
Temperature-corrected total
Petroleum measurement application
only
TCVOL
Temperature-corrected volume
Petroleum measurement application
only
TUBEF
Raw tube frequency
WTAVE
Weighted average
Using the transmitter display
258
Micro Motion
®
Model 2700 Transmitters with Analog Outputs
Содержание MICRO MOTION 2700
Страница 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 142: ...Integrate the meter with the control system 134 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 154: ...Set up the Weights Measures application 146 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 156: ...Operations maintenance and troubleshooting 148 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 327: ...Device Tools Trending Figure C 24 Using ProLink III with the transmitter Configuration and Use Manual 319 ...
Страница 328: ...Using ProLink III with the transmitter 320 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 373: ......