In general, lower damping values are preferable because there is less chance of data loss, and less
lag time between the actual measurement and the reported value.
•
For gas applications, Micro Motion recommends setting
Flow Damping
to 2.56 or higher.
The value you enter is automatically rounded down to the nearest valid value. Valid
damping values are shown in the following table.
Valid values for Flow Damping
Table 4-2:
Core processor type
Update Rate
setting
Valid damping values
Standard
Normal
0
,
0.2
,
0.4
,
0.8
, ...
51.2
Special
0
,
0.04
,
0.08
,
0.16
, ...
10.24
Enhanced
Not applicable
0
,
0.2
,
0.4
,
0.8
, ...
51.2
Effect of Flow Damping on volume measurement
Flow Damping
affects volume measurement for liquid volume data.
Flow Damping
also affects
volume measurement for gas standard volume data. The transmitter calculates volume
data from the damped mass flow data.
Interaction between Flow Damping and Added Damping
In some circumstances, both
Flow Damping
and
Added Damping
are applied to the reported
mass flow value.
Flow Damping
controls the rate of change in flow process variables.
Added Damping
controls
the rate of change reported via the mA output. If
mA Output Process Variable
is set to
Mass
Flow Rate
, and both
Flow Damping
and
Added Damping
are set to non-zero values, flow
damping is applied first, and the added damping calculation is applied to the result of the
first calculation.
4.1.3
Configure Mass Flow Cutoff
Display
Not available
ProLink II
ProLink
>
Configuration
>
Flow
>
Mass Flow Cutoff
ProLink III
Device Tools
>
Configuration
>
Process Measurement
>
Flow
Field Communicator
Configure
>
Manual Setup
>
Measurements
>
Flow
>
Mass Flow Cutoff
Overview
Mass Flow Cutoff
specifies the lowest mass flow rate that will be reported as measured. All
mass flow rates below this cutoff will be reported as 0.
Configure process measurement
Configuration and Use Manual
27
Содержание MICRO MOTION 2700
Страница 10: ...Getting Started 2 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 14: ...Before you begin 6 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 26: ...Configuration and commissioning 18 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 84: ...Configure process measurement 76 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 142: ...Integrate the meter with the control system 134 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 154: ...Set up the Weights Measures application 146 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 156: ...Operations maintenance and troubleshooting 148 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 214: ...Measurement support 206 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 258: ...Troubleshooting 250 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 327: ...Device Tools Trending Figure C 24 Using ProLink III with the transmitter Configuration and Use Manual 319 ...
Страница 328: ...Using ProLink III with the transmitter 320 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 354: ...Default values and ranges 346 Micro Motion Model 2700 Transmitters with Analog Outputs ...
Страница 373: ......