4 Chapter 2 Product Specifications
EV3200 Door Control Inverter User Manual
2.4 Installation Size
Table 2-1 Inverter external size and installation size
Installation size
External size
Inverter model
A (mm)
B (mm)
L (mm)
W (mm)
H (mm)
Installation hole
diameter (mm)
Weight (kg)
EV3200-2S0002A
EV3200-2S0002S
EV3200-2S0004A
EV3200-2S0004S
289 172.5 298 190 60
Φ
4 0.9
2.5 Specifications
Items
Subitems
Specifications
Voltage range
Single-phase AC power, 180V ~ 264V
Input
Frequency range
50Hz ± 5%, 60Hz ± 5%
Voltage range
Three-phase: 0V ~ input voltage
Frequency range
0Hz ~ 128Hz
Output
Overload ability
150% rated current for 1 minute, 180% rated current for 10 seconds
Load motor type
Three-phase AC asynchronous motor, three-phase AC synchronous motor
Modulation mode
Optimized space voltage vector PWM modulation
Control algorithm
Sensorless vector control, vector control with speed sensor
Operation mode
Two modes: 1. The inverter operates as an inverter specially used for controlling the elevator door
(elevator door control mode), 2. The inverter operates as a general purpose inverter
Frequency
resolution
Digital setting: 0.01Hz
Door width auto
learning
The inverter operates at the auto-learnt speed, and operates in the logic procedure of close door (CD)
→
open door (OD)
→
CD
→
stop. After the auto-learning operation, the door width information is saved
and the auto learning process is over
Auto tuning of
motor's
parameters
Purpose of auto tuning function of inverter is to obtain the motor's parameters automatically, and these
parameters will be saved automatically after the tuning process is over
Main control
functions
Speed-adjusting
range
Under rated load condition, 1:100 for vector control with speed sensor; 1:50 for sensorless vector
control
OD, CDcontrol
command input
Terminal control mode; keypad control mode; communication control mode (reserved)
Frequency setting
Set the frequency via keypad; communication control mode (reserved)
Multi-function
terminal input
signal
External reset signal, light curtain signal, safety edge signal, OD position limiting signal, CD position
limiting signal, OD speed decrease signal, CD speed decrease signal, OD prohibition signal, torque
maintaining signal, slow OD and CD signals, lock signal, emergency firemen service (EFS) signal, rush
hour operation enable operation, operation enable signal, auto-learning command signal
Operation
functions
Output signal
3 relay-output: 250Vac/2A (cos
Φ
=1), 250Vac/1A (cos
Φ
=0.4), 30Vdc/1A
Display
4-digit LED display
Running frequency, reference frequency, output voltage, output current, output torque, DC bus voltage,
status of input terminals, status of output terminals, door-operating position (pulse number)