12 Chapter 4 Operation
EV3200 Door Control Inverter User Manual
Chapter 4 Operation
This chapter tells how to use the operation keypad of the inverter, and introduces the basic application of the inverter.
4.1 Operation
4.1.1 Operation Keypad
LED
Programming key
Shift key
OD key
CD key
Digit modification key
Function and data
switchover key
Save key
Stop key
Reset key
Figure 4-1 Operation keypad
Table 4-1 Operation keypad key runctions
Key
Name
Function
Programming
Switches between stopping
status/operating status and programming
state.
Function
/Data
Select data monitor mode and data input
confirmation
Up Increase
Down Decrease
Shift
In the status of RUN and STOP, press this
key to select the parameters that you want
to display on the screen; when setting
data, press this key to select the digit you
want to modify
OD key
In the keypad control mode, pressing this
key opens the door (or initiates forward
(FWD) spinning)
CD key
In the keypad control mode, pressing this
key closes the door (or initiates reverse
(REV) spinning)
Stop/Reset
In the keypad control mode, press this key
to stop operating, or to reset and exit fault
alarming status.
Note
1. In the
keypad control mode of elevator-door control, pressing
the
key opens the door, pressing the
key closes the door.
2. Under general-purpose inverter keypad mode, pressing the
key initiates forward spinning, pressing the
key initiates
reverse spinning.
4.1.2 Description Of Inverter Operating Status
An inverter has 4 operating status.
Stopping status-The inverter is switched on, has no
fault, but without any operation.
Programming state-Use operation keypad to modify
and set function parameters.
Operating status-The inverter's output terminals U, V
and W have electricity outputs.
Fault alarming status-When fault occurs either from
external equipment, internal or wrong operation, the
inverter's LED will display the fault code and lock
output.
4.1.3 Description Of Inverter Operating Mode
The inverter has 4 operating modes: speed control, distance
control 1, distance control 2, distance control 3.