Chapter 2 Product Specifications 3
EV3200 Door Control Inverter User Manual
Chapter 2 Product Specifications
This chapter provides model description and specifications of the inverter.
2.1 Model Description
The following figure provides the model description of the inverter.
EV3200 - 2 S 0004 A
Drive series
Code
Voltage level
220V
2
Input Volt
Single-phase
Code
S
Code
Load type
Asynchronous motor for
elevator door control
Code
Motor power (kW)
0004
0002
0.4
0.2
A
S
Synchronous motor for
elevator door control
Figure 2-1 Inverter model description
2.2 Nameplate
The nameplate is on the bottom of the inverter enclosure, as shown in Figure 2-1.
-2S0002A
0.2kW
1PH AC 200~240V
3PH AC 0~240V
Hz 0.5kVA 1.3A
MODEL:
POWER:
INPUT:
00
OUTPUT:
S/N:
-2
0.2kW
1PH AC 200~240V
2.65A 50/60Hz
3PH AC 0~240V
Hz 0.5kVA 1.3A
00
-2
0.2kW
1PH AC 200~240V
3PH AC 0~240V
Hz 0.5kVA 1.3A
00
EV3200 -2
0.2kW
1PH AC 200~240V
2.65A 50/60Hz
3PH AC 0~240V
0~128 Hz 0.5kVA 1.3A
Drive model
Motor capacity
Rated input voltage,
current and frequency
00
Emerson Network Power Co., Ltd.
Rated output capacity, current,
frequency range and voltage
Bar code
Figure 2-2 Inverter nameplate
2.3 Models
Inverter model
Rated input current (A)
Rated capacity (kVA)
Rated output current (A)
Motor power (kW)
EV3200-2S0002A
EV3200-2S0002S
2.65 0.5
1.3
0.2
EV3200-2S0004A
EV3200-2S0004S
5.3 1.0
2.5
0.4