E300 Installation and Commissioning Guide
109
Issue Number: 1
Motor control
B25
A24
15 way sub-D
connector
Symmetrical
Current Limit
A20
Number Of Motor Poles
B04
Motor Rated Power Factor
A19
Motor Rated Voltage
A22
Motor Rated Speed
A18
Motor Rated Current
A21
Motor Rated Frequency
B20
Motor Rated Thermal
Time Constant 1
Motor parameters
_
+
L1
L2
L3
_
+
U
V
W
Resistor
(optional)
Drive
A51
+
BR
_
Power stage
Open Loop
Control Mode
B09
Low Frequency
Voltage Boost
B12
OL>Motor-voltage control
Calculated
Nominal
Motor
Speed
A25
A08
Maximum Switching
Frequency
Output Frequency
Torque
Producing
Current
Total Output
Current
Magnetizing
Current
RFC-A,
RFC-S
J37
J24
A04
J32
J39
J09
Speed loop gains
A49
Start speed loop P gain
A50
Start speed loop I gain
A52
Run speed loop P gain
A53
Run speed loop I gain
Speed loop
error
Start current
loop filter
Run current
loop filter
Profile
RFC-A
RFC-S>
speed
Analog
speed reference
Reference
parameter
selected
Drive encoder
speed feedback
Speed
loop
output
J51
Profile generation
A40
Acceleration rate
A41
Deceleration rate
A35
Run Jerk 1
A36
Run Jerk 2
A37
Run Jerk 3
A38
Run Jerk 4
A42
Creep stop deceleration
A39
Creep stop jerk
A12
Encoder type
A13
Encoder auto configuration
A14
Encoder LPR
A15
Encoder power supply
A17
Encoder feedback invert
RFC-A, RFC-S
G51
J60
Output
frequency
Profile generation
Carried out by Elevator
controller in analog
reference mode
OL>
A54
J25
Digital
I02 State
Brake
Control
Output
Brake Control
A47 Brake
Release Delay
A48 Brake
Apply Delay
T25
D03
F02
J31
Analog
Digital
RFC-A
> Motor Parameter
Adaptive Control
C09
Drive Encoder
Feedback Filter
Содержание E300 Series
Страница 211: ......
Страница 212: ...0479 0005 01 ...