44
E300 Installation and Commissioning Guide
Issue Number: 1
Figure 4-3 Size 5 power and ground connections
External
braking
resistor
Thermal
overload
protection
device
BR
+DC
-DC
DC / Brake Connections
BR
External
braking
resistor
Thermal
overload
protection
device
DC -
DC +
L1
L2
L2
L1
L3
U
V
W
Optional EMC
filter
Optional
line reactor
Fuses
L3
Mains
Supply
Motor
Optional ground
connection
Supply
Ground
PE
AC Connections
Motor Connections