Diagnostics Optimization CT MODBUS RTU Technical Data
388
E300 Design Guide
Issue Number: 1
Mode: Open-Loop, RFC-A, RFC-S
Drive Status
(
L01
) shows the present status of the drive. The strings from this parameter are also used by the basic keypad to provide the status
display text.
Drive Warning
(
L02
) is set to one if any of the drive warnings is active, and is defined as:
Drive Warning
(
L02
) =
Braking Resistor Alarm
(
L17
) OR
Motor Overload Alarm
(
L21
) OR
Drive Over Temperature Alarm
(
L22
)
This gives an indication of the elevator drive software activity at the point in time when a travel was last travel was interrupted. The value is reset
when a new travel is started. A travel interrupt is actioned when the drive is disabled early or trips during the travel sequencing. See the table below:
L01
Drive Status
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Maximum
16
Default
Units
Type
8 Bit Volatile
Update Rate
Background write
Display Format
Standard
Decimal Places
0
Coding
RO, Txt, ND, NC, PT, BU
Value
Text
0
Inhibit
1
Ready
2
Stop
3
Scan
4
Run
5
Supply Loss
6
Deceleration
7
DC Injection
8
Position
9
Trip
10
Active
11
Off
12
Hand
13
Auto
14
Heat
15
Under Voltage
16
Phasing
L02
Drive Warning
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Maximum
1
Default
Units
Type
1 Bit Volatile
Update Rate
Background write
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT
L03
Travel Interrupt Code
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Maximum
13
Default
Units
Type
8 Bit Volatile
Update Rate
Background
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT
Содержание 03200106