Optimization CT MODBUS RTU Technical Data
438
E300 Design Guide
Issue Number: 1
Table 9-2 Sub-trip identification
9.6 Displaying trip history
The
E300 Advanced Elevator
drive stores all drive trips for diagnostics along with date and time stamping information in Menu L Diagnostics.
9.6.1 Trip log parameters
Trip log
Trip 0
L29
) through to
Trip 9
L38
) store the 10 most recent trips that have occurred where
Trip 0
L29
) is the most recent and
Trip 9
L38
) is
the oldest trip captured. When a new trip occurs and is captured it is written to
Trip 0
L29
) and all the other trips move down the log, with oldest being
lost.
Sub trip numbers
Some trips have sub-trip numbers which provide more detail on the possible cause for the trip. If a trip has a sub trip number its value is stored in the
sub trip log, i.e.
Trip 0, sub trip number
L61
Trip 9, sub trip number
L70
). If the trip does not have a sub-trip number then zero will be stored in the
sub-trip log.
Table 9-3 Trip history parameters
Date and time
The date and time when each of the trips occur is stored in the date and time log for all trips from Trip 0 through to Trip 9. The format of the date and
time stamping is as follows. The date when each trip occurs is stored in
Trip 0 Date
(
L41
) and
Trip 0 Time
(
L42
) going through to
Trip 9 Date
(
L59
)
and
Trip 9 Time
(
L60
). The date and time are taken from
Date
(
J80
) and
Time
(
J81
).
•
Date: date - month - year 31 - 12 - 99
•
Time: hours : minutes : seconds 23 : 59 : 59
The date and time for the trip log can be selected as detailed in the following table
Table 9-4 Date and Time selector
When the Date, Time Selector = 0 the date and time can be written by the user, and the values are transferred to the real time clocks (RTC) in the
keypad or any option module that support this feature installed to the drive. When Date, Time Selector is changed to any other value, the real time
clocks are allowed to run normally again.
When Date, Time Selector is changed from any value to 0 the date and time from a real time clock, if present, is automatically loaded into the date
and time so this is used as the initial value for editing. If more than one real time clock (RTC) is present the date and time from the keypad is used, if
not then the date and time from the lowest number slot with a real time clock is used.
The Date and Time used for time stamping trips will continue to use the originally selected clock even if the Date, Time Selector is changed until a
drive reset is initiated. If Date, Time Selector has been changed and a reset is initiated the trip dates and times are reset to zero.
Powered up time (ms)
When a trip occurs the time in milliseconds since the drive was powered up is also stored in
Trip Time Identifier
(
L72
) since powered up. The time will
roll over when it reaches 2
31
- 1, if the time is 0 a value of 1 is written.
Source
xx
y
zz
Description
Control system
00
0
01
Control board thermistor 1 over temperature
Control system
00
0
02
Control board thermistor 2 over temperature
Control system
00
0
03
Control board thermistor 3 over temperature
Trip
Sub trip
Date
Time
L29 Trip 0
L61 Trip 0, Sub Trip
L41 Trip 0 Date
L42 Trip 0 Time
L30 Trip 1
L62 Trip 1, Sub Trip
L43 Trip 1 Date
L44 Trip 1 Time
L31 Trip 2
L63 Trip 2, Sub Trip
L45 Trip 2 Date
L46 Trip 2 Time
L32 Trip 3
L64 Trip 3, Sub Trip
L47 Trip 3 Date
L47 Trip 3 Time
L33 Trip 4
L65 Trip 4, Sub Trip
L49 Trip 4 Date
L50 Trip 4 Time
L34 Trip 5
L66 Trip 5, Sub Trip
L51 Trip 5 Date
L52 Trip 5 Time
L35 Trip 6
L67 Trip 6, Sub Trip
L53 Trip 6 Date
L54 Trip 6 Time
L36 Trip 7
L68 Trip 7, Sub Trip
L55 Trip 7 Date
L56 Trip 7 Time
L37 Trip 8
L69 Trip 8, Sub Trip
L57 Trip 8 Date
L58 Trip 8 Time
L38 Trip 9
L70 Trip 9, Sub Trip
L59 Trip 9 Date
L60 Trip 9 Time
Date / Time Selector
Date / Time source
0: Set
Date and time parameters can be written by the user
1: Power
Time since the drive was powered up
2: Running
Accumulated drive running time since the drive was manufactured
3: Acc Power
Accumulated powered up time since the drive was manufactured
4: Local RTC keypad
If a keypad installed to the front of the drive includes a real time clock (RTC) then the date, time from this clock is displayed,
otherwise the date, time is set to zero
Содержание 03200106