Diagnostics Optimization CT MODBUS RTU Technical Data
E300 Design Guide
273
Issue Number: 1
See
T24 Digital I/O 01 Source/Destination
(
F18
).
The Digital I/O Output Select parameters allow the I/O to be selected as an input (0) or an output (1). These parameters are only present for digital I/
O that can be used as an input or output.
See
T24 Digital I/O 01 Output Select
(
F24
).
See
T24 Digital I/O 01 Output Select
(
F24
).
See
T24 Digital I/O 01 Source/Destination
(
F18
).
F23
T29 Digital Input 06 Destination
Mode
Open-Loop, RFC-A, RFC-S
Minimum
A00
Maximum
AB99
Default
G32
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Menu Param Alpha Numeric
Decimal Places
3
Coding
RW, DE, PT, BU
F24
T24 Digital I/O 01 Output Select
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Maximum
1
Default
1
Units
Type
1 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, BU
F25
T25 Digital I/O 02 Output Select
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Maximum
1
Default
1
Units
Type
1 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, BU
F26
T26 Digital I/O 03 Output Select
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW
F27
T41 T42 Relay Output Source
Mode
Open-Loop, RFC-A, RFC-S
Minimum
A00
Maximum
AB99
Default
L05
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Menu Param Alpha Numeric
Decimal Places
3
Coding
RW, PT, BU