Diagnostics Optimization CT MODBUS RTU Technical Data
358
E300 Design Guide
Issue Number: 1
This indicates the maximum motor voltage sampled in the previous travel. The value is taken from
Output Voltage
(
J61
). This value is reset at the
beginning of a new travel.
This parameter may be used to indicate if the motor has gone into field weakening, and therefore a reduction in available motoring torque.
This indicates the maximum motor current sampled in the previous travel. The value is taken from
Torque Producing Current
(
J24
)
.
This value is reset at the beginning of a new travel.
DC. Bus Voltage
(
J65
) gives the voltage across the DC Bus of the drive.
Internal IO Identifier
(
J66
) identifies the internally installed I/O option as given in the table over.
Encoder Feedback Interface Identifier
(
J67
) identifies the type of interface fitted in the position feedback interface option location as given in the table
overleaf.
J63
Last Travel Maximum Motor Voltage
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Maximum
32767
Default
Units
V
Type
16 Bit Volatile
Update Rate
Background
Display Format
Standard
Decimal Places
0
Coding
RO,ND, NC, PT
J64
Last Travel Maximum Current
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0.000
Maximum
32.767
Default
Units
A
Type
32 Bit Volatile
Update Rate
Background
Display Format
Standard
Decimal Places
3
Coding
RO,ND, NC, PT
J65
DC Bus Voltage
Mode
Open-Loop, RFC-A, RFC-S
Minimum
VM_DC_VOLTAGE
Maximum
VM_DC_VOLTAGE
Default
Units
V
Type
16 Bit Volatile
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RO, FI, VM, ND, NC, PT
J66
Internal IO Identifier
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Maximum
255
Default
Units
Type
8 Bit Volatile
Update Rate
Power-up write
Display Format
Standard
Decimal Places
0
Coding
RO,ND, NC, PT, BU
Internal IO Identifier
(J66)
Internal I/O
0
Analog and digital I/O
J67
Encoder Feedback Interface Identifier
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Maximum
255
Default
Units
Type
8 Bit Volatile
Update Rate
Power-up write
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT, BU