26
Terminal Rack Installation
To install the terminal to a rack:
Step 1.
Attach the terminal to the vertical guides of the rack.
Step 2.
Align mounting holes in the support bracket with the corresponding holes in the rack guides. Use
the holes of the same level on both sides of the guides to ensure the terminal horizontal installation.
Step 3.
Use a screwdriver to screw the terminal to the rack.
The terminal is horizontally ventilated. The side panels have air vents. Do not block the air vents to avoid
components overheating and subsequent terminal malfunction.
To avoid overheating and provide necessary ventilation of the terminal, sufficient
space should be provided above and below the terminal, not less than 10 cm.
Fig. 7.2 – Terminal Rack Installation