A. Indoor temperature for opening
In the automatic settings, you must indicate at first the lightness from which shading
shall start.
As soon as the value indicated here is exceeded, the automatic opens the window
(unless the blocking value for the outdoor temperature has fallen below, see next
parameter). The hysteresis is 2°C. That means, that the window will be closed as soon
as the indoor temperature drops 2°C below the set value.
The presetting is 25°C.
Adjust the value with (higher) and (lower) or select
(off) in order to switch off
the function. You reach the setting
by pressing once more when the display
shows “5°C”. If you select
, there is no control in terms of temperature. Therefore,
the following automatic parameter (chapter B) is skipped. The window may be operated
manually and the protection against wind and rain is active (if set accordingly, see
chapter "C. Wind alarm” and “D. Rain alarm”).
Press
in order to get to the setting of the next parameter.