14
1
Cable connection to the rain sensor in the housing cover
2
Connections for the drive mechanism (tension clamp, PE/N/up/down), suitable
for solid conductors up to 1.5 mm² or conductors with fine wires
3
Opening for the cable for the drive mechanism
4
Connections for voltage supply (230 V AC, tension clamp, L1/N/PE), suitable for
massive conductors of up to 1.5 mm² or conductors with fine wires.
5
Opening for the cable for voltage supply
6 Microfuse
6.3
A
7
Programming LED. In normal operation, this LED indicates the receipt of a valid
data package by a short flashing
8
Programming key for the teaching in of the radio connection to the operating unit
Connection of voltage supply and drive mechanism
The drive mechanism of the window is connected to the weather station. Several drive
mechanisms may be connected in parallel. In case of the parallel connection of motors,
please observe whether a group control relay is specified by the motor manufacturer.
Group control relays may be provided by Elsner Elektronik or the motor manufacturer.
ATTENTION!
If motors are connected in parallel which are not suited for this purpose, both
motor and control system are damaged.
Motors with a rated input of more than 1000 Watt must be operated with a relay or
contactor with own feeder.