![Elo TouchSystems DOS and Windows Driver Disk Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/elo-touchsystems/dos-and-windows-driver-disk/dos-and-windows-driver-disk_driver-manual_2395587035.webp)
28
Chapter 4 - DOS Touchscreen Driver and Calibration Utility
Serial Controllers
Command format:
ELODEV <controller>,<COM port>,<baud rate>
where <controller> is:
2300 for the IntelliTouch E281-2300 controller.
4002 for the IntelliTouch E281{A}-4002 controller.
2210 for the AccuTouch E271-2210 controller.
2200 for the AccuTouch and DuraTouch E271-2200 controller.
140
for the AccuTouch E271-140 controller.
280
for the DuraTouch E261-280 controller.
<COM port> is 1 or 2, matching the COM port where the serial output of the
touchscreen controller is connected.
<baud rate> matches the switch or jumper settings on the controller.
For example,
ELODEV 4002,1,9600
It is not necessary to use the DOS MODE command to configure the
communications parameters of the COM port used by ELODEV.
PC-Bus Controllers
Command format:
ELODEV <controller>,<Base I/O Port (hex)>,<IRQ>
Where <controller> is:
4035 for the IntelliTouch E281-4035 controller.
4025 for the IntelliTouch E281{A}-4025 controller.
2201 for the AccuTouch and DuraTouch E271-2201 controller.
141
for the AccuTouch E271-141 or DuraTouch E271-142
controller.
<Base I/O Port> matches the jumper settings on the controller.
NOTE
If you want to use ELODEV with a serial touchscreen controller installed on a
serial port other than COM1 or COM2, you must supply custom code to do so.
See the SetUserCom function in the ELODEV Programmer's Reference for more
information. You may also consider using a PC-Bus controller.