ELODEV Error Messages
117
Invalid syntax.
An argument on the command line was missing or not as expected.
Usually a comma was expected. If you specified a COM port of 0, no baud
rate should be specified. If using a Micro Channel controller, you should
not specify a Base I/O Port or Interrupt (IRQ).
Invalid translation range.
Six signed decimal values must be specified (-r flag).
Invalid wait time flag.
The Untouch Wait Time (-w flag) must be less than 500 (decimal).
Invalid XY swap flag.
The swap flag (-s) must be + or -.
System does not have a Micro Channel bus.
You have specified a Micro Channel controller on a system that is not a
PS/2 or compatible with a Micro Channel bus.
System does not have a PC-Bus.
You have specified a PC-Bus controller on a system that has a Micro
Channel bus.
Touchscreen fault -- controller is transmitting continuously.
The controller should be transmitting only when you touch the
touchscreen. You have a hardware problem. See the IntelliTouch Product
Manual or the AccuTouch Product Manual as appropriate for additional
troubleshooting information.