26/76
MP120
where “xx” indicates whether the buzzer is ON (YES) or OFF (NO). To modify the enable, press
ENTER
and
use button ▼ to select YES or NO, then confirm the new value by pressing
ENTER
.
6. Press ▼. The following message will appear on the display:
where “xx” indicates whether the pre-alarm is ON (YES) or OFF (NO). To modify the enable, press
ENTER
and
use button ▼ to select YES or NO, then confirm the new value by pressing
ENTER
.
7. Press ▼. The following message will appear on the display:
where “xxx” indicates the type of actuation: Standard (Std), Self-exclusion (Aex) or Actuation Lock (Blk). To
modify the type, press
ENTER
and use button ▼ to select the desired type, then confirm the new value by
pressing
ENTER
.
8. Press ▼. The following message will appear on the display:
where “x” indicates whether the masking is ON (S) or OFF (N). To modify the enable, press
ENTER
and use
button ▼ to select S or N, then confirm the new value by pressing
ENTER
.
9. To exit the menu, press
EXIT
.
2.14 TELEPHONE COMMUNICATOR CONFIGURATION
Warning! The configurations described in this paragraph shall be performed only if the PSTNO
telephone communicator is available in the control unit.
2.14.1 PROGRAMMING THE TELEPHONE NUMBERS
To program a telephone number, proceed as follows:
1. type in the Installer code (factory setting: 000000) or the Master code (factory setting: 111111), then press
ENTER
twice.
2. The following message will appear on the display:
Press ► until the message below appears:
Then press
ENTER
to confirm.
3. The following message will appear on the display
Press
ENTER
to confirm.
4. The following message will appear on the display:
where “nnnnnn” is the telephone number (if any) previously stored in the memory.
T 1 : n n n n n n
P h o n e N u m b e r P R G
C o m m u n i c a t o r P R G
E v e n t M e m o r y
M a s k e d S y s t e m N
S e t / U n s e t M o d e x x x
P R E - A L A R M x x