18/76
MP120
Then press
ENTER
to confirm.
3. The message below will appear on the display:
Press ▼ until the message below appears:
Then press
ENTER
to confirm.
4. The auxiliary input of the first expansion will appear. If you wish to program a different input, select it by means
of button ▼.
5. Press
ENTER
to configure the displayed input.
6. Use button ▼ to select the input mode (Failure or NETWORK), then confirm by pressing
ENTER
.
7. Use button ▼ to select another input (start again from step 5) or leave the menu by pressing
EXIT
.
2.8 PROGRAMMING THE OUTPUTS
2.8.1 OUTPUT SPECIALIZATION
The electric outputs – both for the control unit and the expansions – may be programmed in order to be actuated
following certain events. On the contrary, control unit relay output U1 may be programmed only in part, as shown in
the table below.
Control unit output U1 response to the events
Event
System ON
System OFF
Break-in
■
Tampering
■
If programmed
Panic
■
■
Fire
If programmed
If programmed
Possible electric output specializations include the following:
•
Break-in
: it is actuated when a detector signals an attempt at break-in in any of the correlated sectors (the
sector must have been actuated. The actuation time is equal to the programmed alarm time.
•
Tampering
: it is actuated for 1 minute when the system detects tampering (attempt at opening or removing a
device). The output is always ON (24-h).
•
Robbery
: the output is actuated for 1 minute directly by the user, e.g. by pressing a button or disabling, when
the user is being threatened by the criminals, the system with the antitheft code (the last digit of the code will be
increased by one unit, e.g. by typing in ...5 instead of ...4; ...9 will turn to ... 0). This will allow the user to send
out a silent alarm even if he/she is being threatened. Auxiliary devices (e.g. radio transmitter) may be connected
to the electric output. The input is always ON (24-h).
•
Panic
: it is actuated for 1 minute when an input of the “Panic” type is opened. The input is always ON (24-h).
•
Technological
: it is actuated for 1 minute when the detector (flooding, temperature detector, etc.) for an input of
the “Technological” type signals an alarm. The input is always ON (24-h).
•
Fire
: it is actuated for 1 minute when the detector for an input of the “Fire” type signals the start of a fire. The
input is always ON (24-h).
•
Chime
: it is actuated for 5 seconds every time an anti-theft entry is open in which the “Chime” (gong) property
has been enabled. The output will be enabled only when the sector is OFF.
•
Failure
: it is actuated when any type of failure occurs. It will remain ON until the cause of the failure is removed.
•
Battery
: it is actuated when the control unit booster battery voltage is lower than 11.2 V−. It will be deactivated
automatically when the battery voltage exceeds 11.2 V− again.
•
Network
: it is actuated when the 230 V~ network power supply is lacking for the duration established by the “No
mains supply” system parameter. It will be deactivated automatically when the mains supply is resumed.
•
Telephone line status
: it is actuated to signal the lack of the telephone line. Checking is carried out during line
check or tone check prior to sending out an alarm from the telephone interface. Refer to paragraph
2.14.8
Telephone line check
for further information on how the control unit carries out the line check.
•
Reset
: it is actuated for 5 seconds every time the system is actuated. It is used to reset the fire sensors which
will, once a fire start has been detected, remain in the alarm storage status (for storing).
Note:
if an output is
specialized to act as a reset, the inputs powered by
resettable inputs
(e.g.: glass breaking, smoke sensors….)
from the Reset output need be
programmed as delayed inputs
(delay is not programmed for fire sensors).
Otherwise, upon every single actuation, these inputs will, after the sensors have been reset for 3 seconds, be
open, thus generating an alarm.
P r o g . I N o . a u x E X P
Z o n e P r o g r a m m i n g
If additional expansions are
available