3-30 Programming
Timed Outputs
Menu Path
MAIN SCREEN to SETUP MENU to TIMED OUTPUT
Purpose
Any four outputs can be programmed to time out rather than remain on until an OFF
setpoint is reached. This makes the output duration constant regardless of machine
speed. If the OFF setpoint is reached before the specified time has elapsed, the timing
will be aborted and the output will turn off immediately.
Once an output times out, it will not turn on until the next ON setpoint is reached. Each
timed output can have a unique time delay length.
Outputs are timed in one msec increments up to a maximum of 9999 msec (9.999
seconds).
Screen
Pulse Required
A timed output must be programmed with ON and OFF position setpoints in order for
output timing to take effect.
Reverse Rotation
If the machine is rotating in the reverse direction, timed outputs will energize when the
OFF edge of the pulse occurs.
Toggle RPM
Menu Path
MAIN SCREEN to CONFIG MENU to DISPLAY MENU
to TOGGLE RPM
Purpose
Toggle RPM is the resolver speed at which the Position display on the Main Screen
will disappear. At speeds below the Toggle RPM the Position display will be visible; at
speeds above the Toggle RPM the Position will not be shown.
Screen
Programming
Use the numeric keys and ENT to enter a new value, or use INC and DEC to change
an existing value.
CHANNEL: 1
TIME(mS): 20
Channel
Time duration
TOGGLE
RPM: 50
Toggle RPM: Position display on main screen
is not shown at speeds above Toggle RPM
Содержание Plus PS-6144 Series
Страница 3: ......
Страница 4: ......
Страница 12: ...2 2 Installation Wiring Mounting Dimensions Figure 4 Mounting Dimensions ...
Страница 76: ...6 2 Communications PLµSNET II Program cont d Sample ASCII Program Copied from PS 6144 Using PLµSNET II ...
Страница 114: ......
Страница 115: ......
Страница 116: ...800 228 5487 U S A and Canada Web Site www electrocam com email ecam electrocam com PRINTED IN U S A 256 9 14 ...