3-21 Programming
Password (Contʼd)
Clearing a Password
When programming operations are completed, enter a password value of “0,” then ENT
to clear the enable level.
If a keypad is left unattended with an active password, the access code will clear after
five minutes of keypad inactivity and the keypad will revert to the “Normal Display” mode
shown in Figure 21.
See Also
ENABLE CODES
Per Channel Enable
Menu Path
MAIN SCREEN to CONFIG MENU to PGM ENABLES
to PER CHN ENABLE
Purpose
This screen is used to enable Operator Level access to individual output channels. PER
CHN ENABLE is used in conjunction with the ENABLE OPTIONS screen to assign
Operator Level access to selected programming functions.
Screen
CHN: 12<
CHN ENABLE: ON
Channel number
Per channel enable: ON/OFF
(Toggle with SEL key)
Channel Select
Press the INC/DEC keys, or use the numeric keys and ENT.
Enable Toggle
Press the SEL key to toggle the enable ON or OFF.
See Also
ENABLE OPTIONS
Program Copy
Menu Path
MAIN SCREEN to SETUP MENU to PGM COPY
Purpose
Program Copy allows you to copy all of the channels and setpoints from one program
to another. It is often easier to copy an existing program and modify it, than to enter a
new program from scratch.
Screens
The Program Copy function consists of four screens:
Programming
Use the numeric keys and SEL to enter program numbers. During programming, the
cursor keys allow you to move between the Source and Destination screens to allow
you to change values before selecting EXECUTE.
SRC PROGRAM:---<
Program to be copied from
DST PROGRAM:---<
Destination to be copied to
DST PROGRAM: 6<
EXECUTE<
Move cursor to EXECUTE, then press SEL
to copy program
DST PROGRAM: 6
COMPLETE<
COMPLETE indicates program
successfully copied
Содержание Plus PS-6144 Series
Страница 3: ......
Страница 4: ......
Страница 12: ...2 2 Installation Wiring Mounting Dimensions Figure 4 Mounting Dimensions ...
Страница 76: ...6 2 Communications PLµSNET II Program cont d Sample ASCII Program Copied from PS 6144 Using PLµSNET II ...
Страница 114: ......
Страница 115: ......
Страница 116: ...800 228 5487 U S A and Canada Web Site www electrocam com email ecam electrocam com PRINTED IN U S A 256 9 14 ...