6-9 Communications
CMD
(hex) Name
Function
22 Spt Count
Return number of pulses.
Cmd:
! ADR
22 CSM <CR>
Reply:
A XXXX CSM <CR>
where “XXXX” is the total number of pulses in hex. Includes all
pulses in all channels and programs in the controller.
23 Wipe Spt
Deletes all pulses from EEPROM.
Cmd:
! ADR
23 CSM <CR>
Reply:
A <CR>
24 Get Spt
Return program, channel, and on/off points for the specified
pulse.
Cmd:
! ADR
24 XXXX CSM <CR>
Reply:
A XX YY ZZZZ TTTT CSM <CR>
where “XXXX” is the number of the pulse in hex. Pulses are
numbered starting at Channel 1, Program 1, Position 0. As
the transducer rotates through a complete cycle, each pulse
encountered is numbered sequentially. After one cycle, the
pulses in Channel 2 are numbered, and so on.
In the reply, “XX” is the program number of the specified pulse,
minus one. “YY” is the channel number, minus one. “ZZZZ” and
“TTTT” are the “on” and “off” points of the pulse, respectively. All
values are in hex.
25 Add Spt
Adds a setpoint.
Cmd:
! ADR
25 XX YY ZZZZ TTTT CSM <CR>
Reply:
A <CR>
where “XX” is the program number minus one, and “YY” is the
channel number minus one. “ZZZZ” and “TTTT” are the “on” and
“off” points of the pulse, respectively. All values are in hex.
26 Del Spt
Deletes a setpoint.
Cmd:
! ADR
26 XX YY ZZZZ TTTT CSM <CR>
Reply:
A <CR>
where “XX” is the program number minus one, and “YY” is the
channel number minus one. “ZZZZ” and “TTTT” are the “on” and
“off” points of the pulse, respectively. All values are in hex.
27 Mod Spt
Modifies one edge of a setpoint.
Cmd:
! ADR
27 XX YY ZZZZ TTTT MM NNNN CSM <CR>
Reply:
A <CR>
where “XX” is the program number minus one and “YY” is the
channel number minus one.
“ZZZZ” and “TTTT” are the
current “on” and “off” points of the
pulse, respectively.
“MM” is the edge to be modified: “00” is the “off” edge, “01” is the
“on” edge.
“NNNN” is the new value for the specified edge. All values are in
hex.
Setpoint
Commands
Serial Commands (cont’d)
Содержание Plus PS-6144 Series
Страница 3: ......
Страница 4: ......
Страница 12: ...2 2 Installation Wiring Mounting Dimensions Figure 4 Mounting Dimensions ...
Страница 76: ...6 2 Communications PLµSNET II Program cont d Sample ASCII Program Copied from PS 6144 Using PLµSNET II ...
Страница 114: ......
Страница 115: ......
Страница 116: ...800 228 5487 U S A and Canada Web Site www electrocam com email ecam electrocam com PRINTED IN U S A 256 9 14 ...