3-14 Programming
Motion ANDing
Menu Path
MAIN SCREEN
to CONFIG MENU
to CHN ANDING MENU
to MOTION ANDING
Purpose
This function is used to tie the operation of output channels to the Motion Detection levels
programmed through MOTION DETECTION. Each output channel may be ANDed with
either Motion Detection level. If an output is Motion ANDed, it will turn on only when the
resolver RPM is in the range specified for that Motion Detection level, AND the setpoints
programmed for that channel are “on.”
Outputs that must always operate, regardless of machine speed, should not
be ANDed
with a Motion Detection level.
Screen
CHN: 12
MOTION AND: L1
Channel number
Motion ANDing level: L1, L2, or OFF.
(Toggle with SEL key)
This screen displays the channel number and the Motion Detection level for Motion
ANDing: L1, L2, or OFF. The channel will not be Motion ANDed if the enable is OFF.
Memory Tests
Menu Path
MAIN SCREEN
to TEST MENU
to MEMORY TESTS
Purpose
This menu selection provides three functions that allow you to clear programmed
values from the controller. An additional function tests the controllerʼs watchdog timer.
Screen
Programming
To perform one of the memory test functions, enter the function number using the nu-
meric keys and press SEL.
Function 7000
Clears all setpoints and configuration settings from the controllerʼs EEPROM. After
clearing the setpoints, the controller will reload the factory default settings listed in the
Appendix.
Function 7001
Clears all configuration settings from the controllerʼs EEPROM. These include all of
the programming performed through the Setup Menu and Config Menu on the menu
tree, Figure 20. When finished, the controller will reload the factory default settings listed
in the Appendix.
Function 7002
Clears all setpoints
from the controllerʼs EEPROM. These include any on/off setpoints
programmed through SETPOINTS. All other settings will remain intact.
Function 7998
Watchdog Timer Test
. The “Watchdog Timer” monitors the operation of the controllerʼs
microprocessor and shuts the controller down if any internal malfunction is detected. If the
Watchdog Timer fails, the controller may continue to operate. However, any subsequent
malfunctions or noise-induced irregularities may go undetected, and the controller may
begin to operate erratically.
To test the Watchdog Timer, run Function 7998. If the controllerʼs Watchdog Timer is
working properly, the controller will reset. If Function 7998 does not reset the controller,
the Watchdog Timer has failed. Replace the controller immediately and return the faulty
unit to the factory.
Failure of controller to pass the watchdog timer test can cause erratic operation,
resulting in injury and damage to equipment.
MEMORY TESTS
FCN:----<
Enter function here
Содержание Plus PS-6144 Series
Страница 3: ......
Страница 4: ......
Страница 12: ...2 2 Installation Wiring Mounting Dimensions Figure 4 Mounting Dimensions ...
Страница 76: ...6 2 Communications PLµSNET II Program cont d Sample ASCII Program Copied from PS 6144 Using PLµSNET II ...
Страница 114: ......
Страница 115: ......
Страница 116: ...800 228 5487 U S A and Canada Web Site www electrocam com email ecam electrocam com PRINTED IN U S A 256 9 14 ...