3-15 Programming
Motion ANDing (Contʼd)
Programming
Select a new channel by pressing the INC/DEC keys, or through direct numeric entry
followed by ENT.
Press the SEL key to toggle the ANDing to L1, L2, or OFF.
Operation
• Any number of output channels can be ANDed to a single Motion Detection level.
• Motion ANDing and Output Enable ANDing can be combined for any given output
channel.
• When Motion ANDing is activated for a channel, it will apply to that channel in all
programs.
Motion Detector
An output channel can be used as a motion detector by programming it to be on at “1”
and off at “1,” and then ANDing it with the desired Motion Level. This will turn the output
on constantly as long as the machine speed is within the specified Motion Level range.
See Also
MOTION DETECTION
Motion Detection
Menu Path
MAIN SCREEN
to SETUP MENU
to MOTION DETECT
Background
Motion Detection establishes one or two “Motion Levels,” or speed ranges, with low and
high RPM values. These two ranges are independent of each other.
Each output channel can be ANDed with either Motion Level. ANDed outputs will be
enabled only when the resolver speed is within the specified speed range. Output
channels that are not ANDed will be “on” whenever the machine position is within their
programmed setpoints, regardless of machine speed. One use of Motion Levels and
Motion ANDing is to turn off devices such as glue guns if the machine stops or jams.
The MOTION DETECTION function is used to establish one or two Motion levels. Once
the Motion Levels are programmed, use MOTION ANDING to tie individual output
channels to the Motion Levels.
Screen
The Motion Detection screen displays the Motion Level, the Low RPM, and the High
RPM.
Programming
Use the numeric keys and ENT to change values for Motion Level, Low RPM, and High
RPM.
Motion Detector
An output channel can be used as a motion detector by programming it to be on at “1”
and off at “1,” and then ANDing it with the desired Motion Level. This will turn the output
on constantly as long as the machine speed is within the specified Motion Level range.
See Also
MOTION ANDING
MOTION LEVEL: 1
LO: 30 HI: 1500
Motion detection level
High RPM setpoint
Low RPM setpoint
Содержание Plus PS-6144 Series
Страница 3: ......
Страница 4: ......
Страница 12: ...2 2 Installation Wiring Mounting Dimensions Figure 4 Mounting Dimensions ...
Страница 76: ...6 2 Communications PLµSNET II Program cont d Sample ASCII Program Copied from PS 6144 Using PLµSNET II ...
Страница 114: ......
Страница 115: ......
Страница 116: ...800 228 5487 U S A and Canada Web Site www electrocam com email ecam electrocam com PRINTED IN U S A 256 9 14 ...