6-7 Communications
CMD
(hex) Name
Function
1A Spd Cmp Mode
Standard or Leading/Trailing mode.
Put:
! ADR
1A P <00 or 01> CSM <CR>
Reply:
A <CR>
Get:
! ADR
1A G CSM <CR>
Reply:
A <00 or 01> CSM <CR>
where “00” = Standard, “01” = Leading/Trailing
1B Spd Cmp Val
Speed comp value.
Put:
! ADR
1B P XX YYYY ZZZZ CSM <CR>
Reply:
A <CR>
Get:
! ADR
1B G XX CSM <CR>
Reply:
A YYYY ZZZZ CSM <CR>
where “XX” is the channel minus 1, in hex. “YYYY” is the value in
tenths of a msec for the leading edge, and “ZZZZ” is the value
for the trailing edge. For standard speed comp, “YYYY” = “ZZZZ”.
“Y” and “Z” values are hex.
4B Analog Qty
Number of analog outputs used.
Put:
! ADR
4B P XX CSM <CR>
Reply:
A <CR>
Get:
! ADR
4B G CSM <CR>
Reply:
A XX CSM <CR>
where “XX” is the number of analog outputs used. “XX” can be
00, 01, or 02.
1C Analog
Analog values.
Put:
! ADR
1C P XX YYYY ZZZZ CSM <CR>
Reply:
A <CR>
Get:
! ADR
1C G XX CSM <CR>
Reply:
A YYYY ZZZZ CSM <CR>
where “XX” is the channel minus one, in hex. “YYYY” is the Offset
from 0 to 4095, converted to hex. “ZZZZ” is the High RPM in hex.
1D Grp Qty
Output group quantity.
Put:
! ADR
1D P XX CSM <CR>
Reply:
A <CR>
Get:
! ADR
1D G CSM <CR>
Reply:
A XX CSM <CR>
where “XX” is the number of output groups, from one to six.
4A Offset Mode
One offset for all groups, or individual offset for each group.
Put:
! ADR
4A P <00 or 01> CSM <CR>
Reply:
A <CR>
Get:
ADR
4A G CSM <CR>
Reply:
A <00 or 01> CSM <CR>
“00” = Each; “01” = One.
Serial Commands (cont’d)
Configuration
Commands
(cont’d)
Содержание Plus PS-6144 Series
Страница 3: ......
Страница 4: ......
Страница 12: ...2 2 Installation Wiring Mounting Dimensions Figure 4 Mounting Dimensions ...
Страница 76: ...6 2 Communications PLµSNET II Program cont d Sample ASCII Program Copied from PS 6144 Using PLµSNET II ...
Страница 114: ......
Страница 115: ......
Страница 116: ...800 228 5487 U S A and Canada Web Site www electrocam com email ecam electrocam com PRINTED IN U S A 256 9 14 ...