2-8 Installation & Wiring
Output Wiring
Output Types
The outputs available depend on the PS-6144 Model:
Output
Model Model
Type
6144-24M17
6144-24-X16-M09
Transistor
None
Outputs 1-16
AC/DC/RR Modules Only
Outputs 1-15
Outputs 17-23
AC/DC/RR or Analog Modules Outputs 16 & 17
Outputs 24 & 25
The load device to be driven must match the output type.
Power Output Modules
Output modules can directly switch inductive loads and resistive loads that require more
current or voltage than the transistor outputs can supply.
The modules do not supply
the power for the load; they simply switch it. Each output module has two dedicated
terminals and therefore does not share any common signal with the other modules. This
allows AC and DC modules to be mixed on the same control. DC modules can be wired
to sink or source as shown in Figure 9.
Analog Output Modules
Analog output modules generate signals that are proportional to the resolver RPM.
They can be used only in the output positions shown above. Either a 0-10 VDC or 4-20
mA analog module can be used in either module position. ANALOG QTY must be pro-
grammed for the number of analog modules installed. An external power supply is not
needed because the analog modules get the power they source from the controller. The
analog output signal is completely isolated.
Transistor Outputs
PS-6144-24-X16-M09 models include 16 transistor outputs to drive the electronic input
circuits of other control devices. The outputs are limited to 30 VDC, 50 mA each and
should not be used to control inductive devices such as solenoids, solenoid valves or
relays.
The control can be ordered with either sinking or sourcing transistor outputs. Both types
require a 10-30 VDC power supply connected to TB 11 to drive the transistor output
circuitry. The transistor output fuse will blow if the power supply polarity is incorrect,
but the circuitry will not be damaged. See Figs. 17 & 18 for fuse and transistor chip
replacement.
Sinking transistor outputs (N16 controls, Figure 10) conduct to the negative terminal
of TB 11. Therefore the common for TB 11 and the load must be electrically the same.
This may require connecting commons together if the power supplied to TB 11 is not
also the load power supply. Electronic counters/ratemeters often fall into this category.
The power supply that powers the load does not have to be the same voltage as the
transistor power supplied to TB 11.
Sourcing transistor outputs (P16 controls, Figure 11) conduct to the positive power
terminal of TB 11. The load is therefore powered from the same supply that is providing
the transistor power.
Содержание Plus PS-6144 Series
Страница 3: ......
Страница 4: ......
Страница 12: ...2 2 Installation Wiring Mounting Dimensions Figure 4 Mounting Dimensions ...
Страница 76: ...6 2 Communications PLµSNET II Program cont d Sample ASCII Program Copied from PS 6144 Using PLµSNET II ...
Страница 114: ......
Страница 115: ......
Страница 116: ...800 228 5487 U S A and Canada Web Site www electrocam com email ecam electrocam com PRINTED IN U S A 256 9 14 ...