61
EtherNet/IP On-Board Communications
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Assembly instances implemented by PowerXL DG1 EtherNet/IP
Assemblies 20, 21, 23 & 25 ODVA AC/DC profile; assemblies 70, 71, 73 & 75 ODVA AC/DC profile;
assemblies >100, Eaton profile.
Output instances
Assembly instance 20
Table 75. Instance 20 (Output) length = 4 bytes
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
FaultReset
RunFwd
1
2
Speed reference (Low Byte), rpm
3
Speed reference (High Byte), rpm
Assembly instance 21
Table 76. Instance 21 (Output) length = 4 bytes
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
NetRef
NetCtrl
FaultReset
RunRev
RunFwd
1
2
Speed reference (Low Byte), rpm
3
Speed reference (High Byte), rpm
Assembly instance 23
Table 77. Instance 23 (Output) length = 6 bytes
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
NetRef
NetCtrl
FaultReset
RunRev
RunFwd
1
2
Speed reference (Low Byte), rpm
3
Speed reference (High Byte), rpm
4
Torque reference (Low Byte), Nm
5
Torque reference (High Byte), Nm
Torque Reference is sent to the Drive only if Motor Control Mode is set to “Torque Control”.
ote:
N
Torque Reference is sent to the Drive as a Process Data 1.
Assembly instance 25
Table 78. Instance 25 (Output) length = 6 bytes
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
NetRef
NetCtrl
FaultReset
RunRev
RunFwd
1
2
Speed reference (Low Byte), rpm
3
Speed reference (High Byte), rpm
4
Process reference (Low Byte)
5
Process reference (High Byte)
In Speed control Mode—Process Ref is Process Data IN8 (Analog Input 1).
In Freq. control—Process Ref is Process Data IN8 (Analog Output 1, reading the actual output current.).
In Torque control—Process Ref is Process Data IN1 (Torque Reference).
Based on selection of AO, process reference value will be sent on AO out.
Содержание PowerXL Series
Страница 1: ...Effective June 2018 Supersedes October 2017 Communication manual PowerXL Series VFD...
Страница 24: ...xxiv S curit du moteur et de l quipement POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 149: ...125 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com Figure 53 DeviceNet parameters...
Страница 202: ...178 Commissioning POWERXL SERIES VFD MN040010EN June 2018 www eaton com Fault tracing Figure 74 Fault tracing...
Страница 253: ...229 Appendix D PowerXL Recommended Secure Hardening Guidelines POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 254: ...230 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 255: ...231 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...