179
Appendix A—Parameter ID list
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Appendix A—Parameter ID list
Parameter descriptions
Notes
These parameters are active in the DG1 FR7 and FR8 units only.
These parameters are not active in the DG1 FR7 and FR8 units only.
Table 205. DG1 Parameter ID list
Menu
Item
No.
Modbus
Register
PROFIBUS
EtherNet/IP
DeviceNet
Parameter
Description
Data
Type
Length
(in Bytes)
Display
Format
PNU
PNU
SubIndex
Class Instance Attribute Class Instance Attribute
M1
1
502
0
160
1
1
160
1
1
Output Frequency
INTEGER
2
x100
M2
24
1
0
160
1
2
160
1
2
Freq Reference
INTEGER
2
x100
M3
2
503
0
4
70
3
4
70
3
Motor Speed
INTEGER
2
x0
M4
3
504
0
160
1
4
160
1
4
Motor Current
INTEGER
2
x10
M5
4
507
0
160
1
5
160
1
5
Motor Torque
INTEGER
2
x10
M6
5
513
1
160
1
6
160
1
6
Motor Power
INTEGER
2
x10
M7
6
501
0
160
1
7
160
1
7
Motor Voltage
INTEGER
2
x10
M8
7
501
1
160
1
8
160
1
8
DC-link Voltage
INTEGER
2
x0
M9
8
822
6
160
1
9
160
1
9
Unit Temperature
INTEGER
2
x10
M10
9
822
4
160
1
10
160
1
10
Motor Temperature
INTEGER
2
x10
M11
15
2
1
160
1
11
160
1
11
Torque Reference
INTEGER
2
x10
M12
10
560
0
160
1
12
160
1
12
Analog Input 1
INTEGER
2
x100
M13
11
560
1
160
1
13
160
1
13
Analog Input 2
INTEGER
2
x100
M14
25
570
0
4
75
3
4
75
3
Analog Output 1
INTEGER
2
x100
M15
575
570
1
160
1
15
160
1
15
Analog Output 2
INTEGER
2
x100
M16
12
760
0
160
1
16
160
1
16
DI1, DI2, DI3
BYTE
1
x0
M17
13
760
1
160
1
17
160
1
17
DI4, DI5, DI6
BYTE
1
x0
M18
576
760
2
160
1
18
160
1
18
DI7, DI8
BYTE
1
x0
M19
14
754
0
160
1
19
160
1
19
DO1,Virtual
RO1,Virtual RO2
BYTE
1
x0
M20
557
762
0
160
1
20
160
1
20
RO1, RO2, RO3
BYTE
1
x0
M21
558
763
0
160
1
22
160
1
21
TC1, TC2, TC3
BYTE
1
x0
M22
559
3125
0
160
1
23
160
1
22
Interval 1
BOOLEAN 1
x0
M23
560
3125
1
160
1
24
160
1
23
Interval 2
BOOLEAN 1
x0
M24
561
3125
2
160
1
25
160
1
24
Interval 3
BOOLEAN 1
x0
M25
562
3125
3
160
1
26
160
1
25
Interval 4
BOOLEAN 1
x0
M26
563
3125
4
160
1
27
160
1
26
Interval 5
BOOLEAN 1
x0
M27
569
3101
0
160
1
28
160
1
27
Timer 1
DOUBLE
4
x0
M28
571
3101
1
160
1
29
160
1
28
Timer 2
DOUBLE
4
x0
M29
573
3101
2
160
1
30
160
1
29
Timer 3
DOUBLE
4
x0
M30
16
2150
0
160
1
31
160
1
30
PID1 Set Point
DOUBLE
4
x100
M31
18
2864
0
160
1
32
160
1
31
PID1 Feedback
DOUBLE
4
x100
M32
20
2167
0
160
1
33
160
1
32
PID1 Error Value
DOUBLE
4
x100
M33
22
2124
0
160
1
34
160
1
33
PID1 Output
INTEGER
2
x100
M34
23
2133
0
160
1
35
160
1
34
PID1 Status
BYTE
1
x0
M35
32
2150
1
160
1
36
160
1
35
PID2 Set Point
DOUBLE
4
x100
M36
34
2864
1
160
1
37
160
1
36
PID2 Feedback
DOUBLE
4
x100
M37
36
2167
1
160
1
38
160
1
37
PID2 Error Value
DOUBLE
4
x100
M38
38
2124
1
160
1
39
160
1
38
PID2 Output
INTEGER
2
x100
M39
39
2133
1
160
1
40
160
1
39
PID2 Status
BYTE
1
x0
M40
26
1911
0
160
1
41
NA
NA
NA
Running Motors
BYTE
1
x0
M41
27
580
0
160
1
42
160
1
41
PT100 Temperture
INTEGER
2
x10
M42
28
NA
NA
160
1
44
160
1
42
Latest Fault Code
BYTE
1
x0
M43
583
790
0
162
1
11
160
1
43
RTC Battery Status
BYTE
1
x0
Содержание PowerXL Series
Страница 1: ...Effective June 2018 Supersedes October 2017 Communication manual PowerXL Series VFD...
Страница 24: ...xxiv S curit du moteur et de l quipement POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 149: ...125 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com Figure 53 DeviceNet parameters...
Страница 202: ...178 Commissioning POWERXL SERIES VFD MN040010EN June 2018 www eaton com Fault tracing Figure 74 Fault tracing...
Страница 253: ...229 Appendix D PowerXL Recommended Secure Hardening Guidelines POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 254: ...230 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 255: ...231 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...