Appendix A—Parameter ID list
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Menu Item
No.
Modbus
Register
PROFIBUS
Parameter Description
Data
Type
Length
(in Bytes)
Display
Format
PNU
PNU
SubIndex
P3.2.39
1411
2862
1
PID2 Superv Lower Limit
DOUBLE
4
x100
P3.2.40
1413
2863
1
PID2 Superv Delay
INTEGER
2
x0
P3.3.1
227
276
0
AO1 Mode
BYTE
1
x0
P3.3.2
146
460
0
AO1 Function
BYTE
1
x0
P3.3.3
149
279
0
AO1 Minimum
BYTE
1
x0
P3.3.4
147
277
0
AO1 Filter Time
INTEGER
2
x100
P3.3.5
150
274
0
AO1 Scale
INTEGER
2
x0
P3.3.6
148
278
0
AO1 Inversion
BOOLEAN
1
x0
P3.3.7
173
275
0
AO1 Offset
INTEGER
2
x100
P3.4.1
228
276
1
AO2 Mode
BYTE
1
x0
P3.4.2
229
460
1
AO2 Function
BYTE
1
x0
P3.4.3
232
279
1
AO2 Minimum
BYTE
1
x0
P3.4.4
230
277
1
AO2 Filter Time
INTEGER
2
x100
P3.4.5
233
274
1
AO2 Scale
INTEGER
2
x0
P3.4.6
231
278
1
AO2 Inversion
BOOLEAN
1
x0
P3.4.7
234
275
1
AO2 Offset
INTEGER
2
x100
P3.5.1
751
2002
0
Logic Function Select
BYTE
1
x0
P3.5.2
752
2000
0
Logic Operation Input A
BYTE
1
x0
P3.5.3
753
2001
0
Logic Operation Input B
BYTE
1
x0
P4.1.1
141
1
8
Keypad Reference
INTEGER
2
x100
P4.1.2
116
621
1
Keypad Direction
BOOLEAN
1
x0
P4.1.3
114
622
1
Keypad Stop
BOOLEAN
1
x0
P4.1.4
1724
NA
NA
Hand Key Enable
BYTE
1
x0
P4.1.5
1679
622
3
Reverse Enable
BYTE
1
x0
P4.1.6
2515
NA
NA
Change Phase Sequence Motor
BYTE
1
x0
P4.1.7
1685
NA
NA
Power Up HOA Select
BYTE
1
x0
P4.1.8
2462
NA
NA
Bumpless Enable
BYTE
1
x0
P4.1.9
2423
NA
NA
Run Delay Time
INTEGER
2
x0
P4.1.10
252
620
0
Start Mode
BYTE
1
x0
P4.1.11
253
620
1
Stop Mode
BYTE
1
x0
P4.1.12
247
117
0
Ramp 1 Shape
INTEGER
2
x10
P4.1.13
248
117
1
Ramp 2 Shape
INTEGER
2
x10
P4.1.14
249
130
1
Accel Time 2
INTEGER
2
x10
P4.1.15
250
134
1
Decel Time 2
INTEGER
2
x10
P4.1.16
267
639
0
Power Loss Function
BYTE
1
x0
P4.1.17
268
151
0
Power Loss Time
INTEGER
2
x10
P4.1.18
2444
NA
NA
2nd Stage Ramp Frequency
INTEGER
2
x100
P4.2.1
254
2227
0
DC-Brake Current
INTEGER
2
x10
P4.2.2
263
2222
0
Start DC-Brake Time
INTEGER
2
x100
P4.2.3
262
2223
0
Stop DC-Brake Frequency
INTEGER
2
x100
P4.2.4
255
2222
1
Stop DC-Brake Time
INTEGER
2
x100
P4.2.5
251
2204
0
Brake Chopper Define
BYTE
1
x0
P4.2.6
266
2214
0
Flux Brake
BOOLEAN
1
x0
P4.2.7
265
2217
0
Flux Brake Current
INTEGER
2
x10
P4.3.1
264
43
0
Skip Range Ramp Factor
INTEGER
2
x10
P4.3.2
256
41
0
Skip F1 Low Limit
INTEGER
2
x100
P4.3.3
257
42
0
Skip F1 High Limit
INTEGER
2
x100
P4.3.4
258
41
1
Skip F2 Low Limit
INTEGER
2
x100
P4.3.5
259
42
1
Skip F2 High Limit
INTEGER
2
x100
P4.3.6
260
41
2
Skip F3 Low Limit
INTEGER
2
x100
P4.3.7
261
42
2
Skip F3 High Limit
INTEGER
2
x100
Table 206. DH1 Parameter ID list, continued
Содержание PowerXL Series
Страница 1: ...Effective June 2018 Supersedes October 2017 Communication manual PowerXL Series VFD...
Страница 24: ...xxiv S curit du moteur et de l quipement POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 149: ...125 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com Figure 53 DeviceNet parameters...
Страница 202: ...178 Commissioning POWERXL SERIES VFD MN040010EN June 2018 www eaton com Fault tracing Figure 74 Fault tracing...
Страница 253: ...229 Appendix D PowerXL Recommended Secure Hardening Guidelines POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 254: ...230 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 255: ...231 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...