PROFIBUS-DP External Communication Cards
POWERXL SERIES VFD
MN040010EN—June 2018 www.eaton.com
Status word 1 (ZSW1)
Table 110. Application status word PROFIdrive, continued
Bit
Value
Significance
Comments
5
1
Quick Stop Not Activated
(No OFF 3)
0
Quick Stop Activated
(OFF 3)
“Quick Stop (OFF 3)” command is present.
6
1
Switching On Inhibited
The drive goes only again in the “Switched On” condition with “No Coast Stop AND No Quick Stop”
followed by “ON.” This means that the “Switching On Inhibited” bit is only set back to zero if the OFF
command is set after “No Coast Stop AND No Quick Stop.”
0
Switching On Not Inhibit
7
1
Warning Present
Warning information present in the service/maintenance parameter; no acknowledgement.
0
No Warning
There is no warning or the warning has disappeared again.
8
1
Speed Error Within Tolerance
Range
Actual value is within a tolerance band; dynamic violations are permissible for t < tmax, e.g.,
n = nset±,
f = fset±, etc.,
tmax may be parameterised
0
Speed Error Out Of Tolerance
Range
9
1
Control Requested
The automation system is requested to assume control (refer to 6.3.11.
0
No Control Requested
Control by the automation system is not possible, only possible at the device or by another interface.
10
1
f Or n Reached Or Exceeded
Actual value ≥ comparison value (set point) which may be set via the parameter number.
0
f Or n Not Reached
11
1
Device Specific
N/A
0
Device Specific
N/A
12
1
Device Specific
N/A
0
Device Specific
N/A
13
1
Device Specific
N/A
0
Device Specific
N/A
14
1
Device Specific
N/A
0
Device Specific
N/A
15
1
Device Specific
N/A
0
Device Specific
N/A
References
References are 16-bit words containing a sign bit and a 15-bit
integer. A negative reference is formed by calculating the 2’s
complement from the corresponding positive reference.
Table 111. References
SN
N2 data type
hex
N2 data type
decimal
N2 data type
percentage
Frequency in
decimal
1
4000
16384
100
50
2
3000
12288
74
37
3
2000
8192
50
25
4
1000
4096
24
12
5
0
0
0
0
6
F000
61440
–25
12
7
E000
57344
–50
25
8
D000
53248
–75
37
9
C000
49152
–100
50
Actual values
Actual values are 16-bit words containing information on
the operation of the drive. The function to be monitored are
selected by a drive parameter. The scaling of the integers
sent to the master as Actual Values depends on the selected
function.
Содержание PowerXL Series
Страница 1: ...Effective June 2018 Supersedes October 2017 Communication manual PowerXL Series VFD...
Страница 24: ...xxiv S curit du moteur et de l quipement POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 149: ...125 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com Figure 53 DeviceNet parameters...
Страница 202: ...178 Commissioning POWERXL SERIES VFD MN040010EN June 2018 www eaton com Fault tracing Figure 74 Fault tracing...
Страница 253: ...229 Appendix D PowerXL Recommended Secure Hardening Guidelines POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 254: ...230 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...
Страница 255: ...231 Hardware speci cation POWERXL SERIES VFD MN040010EN June 2018 www eaton com...