background image

                          

wwww.eaton.com/powerquality  11-41   06-2011  

             

Eaton Profile Genesys Dual-Lift Ergonomic Workstation Installation              vi

 

 

 
5  Service and Support  

 

 

 

Troubleshooting   

 

 

 

 

 

              37 

 

Lift Freezes 

 

 

 

 

 

              37 

 

Error Code Appears on Control Pad  

 

 

              38 

Technical 

Support       38 

 

 

 

Sales Representatives 

 

 

 

 

 

 

38 

   Local 

US 

Representatives 

      38 

   Eaton 

Worcester 

Office 

      38 

   Latin 

America, 

Central/South America & The Caribbean 

 

 

39 

   International 

Distribution 

      39 

 

 

 

Documentation   

 

 

 

 

 

 

40 

 

 

Содержание G110 Series

Страница 1: ...Grommets FG76 FG118 Eaton Profile Genesys Ergonomic Workstation G110 G111 Series 90 and 120 Dual Lift Ergonomic Workstations Eaton Profile Genesys Dual Lift Ergonomic Workstation G110 and G111 Series...

Страница 2: ...rm or by any means electronic or mechanical for any purpose without the express written consent of Eaton Eaton and Profile are registered trademarks and Genesys is a trademark of Eaton Corporation or...

Страница 3: ...ly to Feet 12 Attach Leg Assemblies to Base 13 Attach Leg and Base Support Covers 14 Level Assembled Components 16 Attach Lower Frame 17 Attach Workstation Support 19 Install Rear Surface and Trim Ass...

Страница 4: ...ation vi 5 Service and Support Troubleshooting 37 Lift Freezes 37 Error Code Appears on Control Pad 38 Technical Support 38 Sales Representatives 38 Local US Representatives 38 Eaton Worcester Office...

Страница 5: ...de important information Failure to follow these warnings may cause personal injury and or product damage Italic type Indicates titles of publications or information that the user must supply such as...

Страница 6: ...nesys Ergonomic Workstation Operator s Manual Instructions on how to program operate and troubleshoot the workstation Profile Flat Panel Console System Installation Manual Additional installation inst...

Страница 7: ...ck move and assemble the components of the workstation Adherence to these guidelines will prevent personal injury and potential product damage When lifting units there should be at least one person fo...

Страница 8: ...vided in kit labeled PROKIT43 thru PROKIT46 Front and side views are shown For a complete list of parts refer the section Unpack the Box Contents in Chapter 2 Item Description Part Number Screws 3 8 3...

Страница 9: ...and side views are shown For a complete list of parts refer the section Unpack the Box Contents 3 Eaton Profile Genesys Dual Lift Ergonomic Workstation Installation www eaton com powerquality 11 41 06...

Страница 10: ...ift Ergonomic Workstation are installed in the proper order For further information on any of these steps refer to the detailed instructions in the corresponding section of this manual Topic Refer to...

Страница 11: ...M6 x 10MM Phillips Pan Head 8 91503 18 LINAK DL6 Desklift 1200N 270 lb 2 96241 19 Motor Control Extension Cable 1 96779 20 E Chain 41 Links 2 97352 21 E Chain 53 Links 1 97362 22 Screw Phillips Pan H...

Страница 12: ...all components that are included in the Profile Genesys Dual Lift Ergonomic Workstation shipment Refer to the table on the previous page for a description and quantity of each component 7 Eaton Profi...

Страница 13: ...30 90 Tilt Keyboard Core Only G111C303030 B Dual 30 x 36 x 30 90 G110A303630 B Dual 30 x 36 x 30 90 Tilt Keyboard G111A303630 B Dual 36 x 36 x 36 90 G110A363636 B Dual 36 x 36 x 36 90 Tilt Keyboard G1...

Страница 14: ...ssembly to Feet 12 Attach Leg Assemblies to Base 13 Attach Leg and Base Support Covers 14 Level Assembled Components 16 Attach Lower Frame 17 Attach Workstation Support 19 Install the Rear Surface and...

Страница 15: ...3 4 before you begin the assembly process 1 Turn the lift column upside down as shown in the illustration below Base Step 2x Base Cover DL2 Front of Lift Shown 2 Remove the two screws as shown and ret...

Страница 16: ...of aluminum and the screw holes are susceptible to being easily stripped Step 6 Flip over the assembly so that the base rests on the floor Move and position the assembly close to the final installatio...

Страница 17: ...ight with right NOTE Make sure the levelers are extended at least 3 4 before you begin the assembly process 1 Insert the right leg assembly into the right foot assembly as illustrated below 2 Insert f...

Страница 18: ...support Leg Assembly Support Cover Leg Assembly Base Supports Left and Right 2 Insert eight Phillips head thread form screws 66714 and tighten as shown below Step Step 8x 3 Repeat step 1 to align the...

Страница 19: ...e support cover securing the cover to the base support as illustrated below Four of the Phillips head screws are located at the bottom of the cover and two at the top end as illustrated below 3 Repeat...

Страница 20: ...rews you removed and retained earlier to the base as shown below Step Lift Base Cover Step 2x Step 4x Step Step You have successfully attached the leg and base covers for the Profile Genesys Ergonomic...

Страница 21: ...base levelers are extended at least 3 4 prior to leveling Lift Column DL2 Leg Assemblies DL6 Step Step Step Step Step 2 Using a spirit level bubble level instrument level the unit front to back as wel...

Страница 22: ...he middle front of the lift column loosen the center pre installed Phillips screw 96983 by approximately 0 125 inch IMPORTANT Do not tighten any screws until the frame is level and aligned Step Step S...

Страница 23: ...four 4 screws on the leg assemblies DL6 9 Tighten two 2 side screws on lift column DL2 Ensure unit is properly aligned level and plumb 90 degrees to all lifts and legs 10 Tighten one front screw on th...

Страница 24: ...orkstation support over the left and right leg assemblies 2 Using four lock washers 18950 and four Phillips head screws 91503 per side two sets in the front and two sets in the rear loosely attach the...

Страница 25: ...of two people to align the beam and stabilize it until the fasteners are secure 1 Align the rear surface support beam over the top of the lift column 2 From above the beam insert four TORX M8x35 flat...

Страница 26: ...read form screws 66714 through the cable chain bracket into the bottom of the support beam and tighten to attach the support bracket to the rear surface support beam 3 Attach the top of both cable cha...

Страница 27: ...el Display Configuration Then Drill 2 1 2 Diameter Hole Here See this Configuration in Figure Below 2 over 2 flat panel displays see figure below 6 00 A 3 over 3 flat panel displays 4 over 4 flat pane...

Страница 28: ...front curved panel 22163X or 21616X into the slot in the bottom front of the deck Step 2x 23 Eaton Profile Genesys Dual Lift Ergonomic Workstation Installation www eaton com powerquality 11 41 06 201...

Страница 29: ...ve the rear surface beam using the flat panel display poles and or grommet opening to help with alignment 2 From the bottom of the rear surface insert 17 Phillips head screws 62071 through the support...

Страница 30: ...ace to the support frame 1 Align the pre drilled holes in the bottom of the user surface with the openings in the support frame 2 Insert the Phillips head wood screws 62071 and tighten The number of s...

Страница 31: ...user and rear surfaces to their highest setting 2 Measure the gap between the surfaces to be 1 5 3 If the gap is inconsistent then check if the workstation is level 4 If the unit is not level then lo...

Страница 32: ...surface 1 From below the user surface attach the 53 link cable chain 97632 using two Phillips head screws 62071 to the surface 2 From behind the assembly attach the cable chain to the lower frame usi...

Страница 33: ...Step 4x 2 From the underneath the user surface attach the operator control pad bracket 96239 to the left front of the surface as shown in the illustration below NOTE The control pad can be mounted in...

Страница 34: ...b The mains cable is to be mounted and power switched on Please note that the control box must only be connected to the voltage stated on the label c The control box earth cable should be mounted on...

Страница 35: ...wn below 7 Connect the controllers to the controller port as shown here Port Connections Detail IMPORTANT Note the connection port assignment The workstation will not function unless the lifts are plu...

Страница 36: ...face by inserting three 3 10A x 1 Phillips pan head screws 62071 through the rear cover and into the rear surface and tighten Rear Surface Rear Cover Step 3x 2 The rear cover installation is now compl...

Страница 37: ...of this manual for document location You have now successfully installed and initialized the Profile Genesys Dual Lift Ergonomic Workstation and it is ready for operation For additional operational in...

Страница 38: ...e user surface by hooking the frame to the user surface support frame Step 5x Keyboard Assembly Step 4x User Surface 2 From below the work surface insert four Phillips screws 92927 through the keyboar...

Страница 39: ...To align the workstation to the core do the following 1 Attach the connector base to the lift base using thread forming screws 54348 as shown in the exploded view below 2 Connect the base to the core...

Страница 40: ...s Lift Shown for Reference Only 5 Install the grommet in the grommet opening in the core as shown below 6 Route cables from the lift through the grommet opening in the core as shown below 7 Install co...

Страница 41: ...ezes If the lift freezes and the workstation is not moving in an upward or downward motion then you will need to re initialize the system and it should correct the problem Follow these instructions to...

Страница 42: ...and detailed description of the problem as well as contact information to Technical Support at to support eaton com Sales Representative Contact an Eaton Sales representative by one of the methods be...

Страница 43: ...lands Tel 31 0 20 820 3000 Fax 31 0 20 820 3010 Malaysia Quantum Special Sdn Bhd 2 2 Jalan USJ 1 1B Regalia Business Centre 47610 Subang Jaya Selangor Malaysia Tel 603 8023 3284 Fax 603 8023 4486 Mexi...

Страница 44: ...103 0011 Japan Tel 81 3 5651 8123 Fax 81 3 5651 8170 Documentation For documentation pertaining to this product and related Eaton products visit our website t a http www wrightline com www eaton com...

Страница 45: ...l distributor please visit www eaton com wrightline or call 800 225 7348 Eaton Corporation Electrical Sector 1111 Superior Ave Cleveland OH 44114 United States 877 ETN CARE 877 386 2273 Eaton com 2011...