28 Operation
Initial Settings
If you have been provided with recommended settings for your application, record these
in the spaces provided below for future reference.
Head Temperature ................ _______
Head Dwell Timer .................. _______
Bag Length Timer .................. _______
Film Pre-Feed Delay Timer ... _______
In-Feed Conveyor .................. ______
Exit Conveyor ........................ ______
Upper Power Film Unwind ..... _______
Lower Power Film Unwind ..... _______
Tunnel Speed ........................ _______
Tunnel Temperature .............. _______
Velocity Control ..................... _______
Testing the Bag Length Timer
NOTE: This should be tested with no film!
1. Turn on conveyors and then touch the “Bag Setup” button.
2. Place product onto the infeed conveyor.
3. The Infeed conveyor carries product forward to the L-seal area.
4. The photo eye detects the edge of the product, which begins the countdown of
the Film Prefeed Delay Timer. After the specified delay (or immediately if set to
zero) the power film unwind starts.
5. The product moves into the L-seal area and the conveyor stops. The seal head
will not cycle.
Note where the product stops.
•
If the product is not under the seal head but fully into the seal area, touch
“Bag Setup” and then thread the film.
•
If the product is not fully into the seal area, increase the bag length timer
and try sending the product through again.
Redo this test until you have the right settings for the product you are running.
6. The conveyor will start up again. Touch the “Conveyor Stop” button.
Load and thread the film and run the product. Refer to the following procedure for
loading and threading film.