www.eao.com
17
7.
Mechanical installation/mounting
2 mounting versions are available: Installation in a panel by means of retaining clamps
(retaining clamp version) or screws (screw-in version).
Installation in a panel by means of retaining clamps
(retaining clamp version)
See drawing “
1707 product information (drawing no. 1707940001)
”.
If the keypad is mounted or dismounted several times, new retaining clamps must be used
each time. This prevents the retaining clamps from settling. To change the retaining clamps,
press the clamp flat on the underside, then you can push out and dismount the retaining clamp.
The marking of the retaining clamp for the respective front panel thickness is imprinted as
number 1 to 4 on the clamp, which is also visible when mounted. The number 1 on the retaining
clamp means that it is suitable for a front panel thickness of 1mm. A mixed use of different
types of retaining clamps in a keypad is not permitted.
The keypad shall be pressed evenly into the panel with the mounted retaining clamps, while
tilting should be avoided. Press evenly on the housing and not on the buttons.
Note
Damage to the buttons
The plug-in connection must be established with a suitable connector. The plug-in connection
can alternatively be established before or after mounting the keypad into the panel.
The keypad is automatically centred to the panel by the 6 retaining clamps, i.e. the exact
positioning of the keypad depends on the accuracy of the installation opening.