Technical specification
Validation ongoing and not completed:
Mechanical characteristics
̶
Actuation force:
6,5 N
̶
Overload:
250 N
̶
Service life – Rugged Keypad:
up to 1 million cycles of operation
Electrical characteristics
̶
Operating voltage range:
8-32 VDC
Illumination
̶
LED symbol illumination – colour:
white LED
̶
LED halo ring illumination – colour: RGB
Symbols
̶
Symbols in accordance with ISO 7000
̶
Customer-specific symbols on request
Connections/interfaces
̶
CAN interface (ISO 11898)
̶
CAN protocols:
CANopen (CiA 401), SAE J1939
̶
Baudrate:
250 (default), 500 kb/s (software configurable)
Ambient conditions (validation not yet completed)
̶
Operating temperature:
-40 °C … +85 °C
̶
Storage temperature:
-40 °C … +85 °C
Protection degree
IP6K7 protection (mounted state front: IP6K7; back: IP20 without plugged connector).
Protection degree for assembled situation in responsibility of customer application.
Attention
The protection degree of up to IP67 to be achieved depends on the front
panel and type of mounting and must be ensured by the customer.