www.eao.com
69
Example messages for setting the timing of the fast mode to 20ms LED on after each 50ms:
11-Bit
Identifier DLC
Data field
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
0x60B
8
0x2B
0x06
0x21
0x00
0x14
0x00
0x00
0x00
0x60B
8
0x2B
0x07
0x21
0x00
0x32
0x00
0x00
0x00
Changes between Software version 04.05.001 and 06.03.000
or newer
During further development it was necessary to implement some changes in the software. The
changes for CANopen/CANopenSafety communication are shown in the table below:
Type
Index
Change
04.05.001
06.03.000
Object 0x1009s0 NVM block changed
EAO-only
EOL-ID
Object 0x1010s0 Increased supported subindex to 7
6
7
Object 0x1010s8 New sub-object was added
---
EOL-ID
Object 0x1011s0 Increased supported subindex to 7
6
7
Object 0x1011s8 New sub-object was added
---
EOL-ID
Object 0x2001s0 NVM block changed
EAO-only
EOL-ID
Object 0x2007s1 Adjust Undervoltage limit
8000
7000
Object 0x2007s4 Adjust hysteresis time
80
500
Object 0x2017s0 NVM block changed
EAO-only
EOL-ID
Object 0x2125s0-
s3
New object added
---
New object
Object 0x2996s1-
s3
New development object added
---
New object
Object 0x2997s0-
s3
New development object added
---
New object
Object 0x2999s0-
sD
New development object added
---
New object
Error
Codes
---
The error codes were reduced to the
essential groups
---
---
Object 0x1001s0;
0x1003
Button indices changed
B1 -> 0, B2 -> 2,
B3 -> 4, B4 -> 1,
B5 -> 3, B6 -> 5
B1 -> 0, B2 -> 1,
B3 -> 2, B4 -> 3,
B5 -> 4, B6 -> 5