www.eao.com
51
[source: CiA CANopen® application layer and general communication profile „CAN poster“]
Example of boot up sequence and setting the keypad into operational state right after boot-up
with default values as seen by the CAN master (only SDOs):
CAN-ID
Rx/Tx
DLC Data Byte 0
Data Byte 1
Description
0x70b
Rx
1
0x00
-
Boot-Up
0x70b
Rx
1
0x7F
-
Heartbeat pre-operational
0x000
Tx
2
0x01
0x0b
NMT command to set device with
node ID 0x0b to Operational state
0x70b
Rx
1
0x05
-
Heartbeat Operational