www.eao.com
56
11-Bit
Identifier
DLC
Data field
Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7
0x60B
8
0x23
0x01
0x14
0x01
0x00
0x03
0x00
0x00
After these steps are executed successfully the PDO (if it is a TPDO) will start to transmit
periodically or can be accessed (RPDO) by CAN messages with the given COB-ID.
Example of CAN message transfer writing a value into the mapped object in RPDO2 (as
defined in the examples see above) as seen by the CAN master:
11-Bit
Identifier
DLC Rx/Tx
Data field
Byte 0
0x300
1
Tx
0xFA
10.5.3
Automatic COB-ID update
By default the COB-ID of the Keypad does not change its value if the Node-ID of the Keypad
is changed. If this functionality is needed the keypad offers this function though. To activate
this function the object 0x2005 needs to be changed. By default it is set to 0x00 which means
no automatic change of the COB-IDs. To activate the automatic COB-ID update the customer
will have to change the value of this object to 0x01.
For further information please refer to the current K-Matrix.
Please note that the changing of the COB-ID for the EMCY-message is not affected by this
object. The COB-ID of the EMCY-message will always be updated automatically.