Section E - Symptom/Cause Chart, cont’d.
DUO-THERM BASEMENT HEAT PUMPS...
Continued
96
SYMPTOMS
CAUSE
REFER TO
PAGE
Fan Operates; compressor tries to start,
cycles “OFF” and hums again,
or blows circuit breaker.
Comfort Control Center System
AC Voltage
A1
1
PTCR or Start Relay
C4`
29
Start Capacitor
C3
28
Fan/Run Capacitor
C2
28
Overload
C6
30
Compressor
C5
29
4.Fan operates; compressor runs for a short
while, cycles off, cycles back on hums, blows
circuit breaker or does not run.
Bimetal Thermostat Control System
Operation
B2b
24
AC Voltage
A1
1
PTCR or Start Relay
C4
29
Start Capacitor
C2
28
Fan/Run Capacitor
C2
28
Short Cycle
C22i
59
Air Flow Obstruction
C22j
60
Motor
C5
27
Overload
C6
30
Compressor
C5
29
Sealed System
C20
55
Analog Control System
Operation
B2a
24
AC Voltage
A1
1
PTCR or Start Relay
C4
29
Start Capacitor
C2
28
Fan/Run Capacitor
C2
28
Short Cycle
C22i
59
Air Flow Obstruction
C22j
60
Motor
C5
27
Overload
C6
30
Compressor
C5
29
Sealed System
C20
55
Comfort Control Center System
Operation
B2a
24
AC Voltage
A1
1
PTCR or Start Relay
C4
29
Start Capacitor
C2
28
Fan/Run Capacitor
C2
28
Short Cycle
C22i
59
Air Flow Obstruction
C22j
60
Motor
C5
27
Overload
C6
30
Compressor
C5
29
Sealed System
C20
55