![Duo-Therm 39125 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/duo-therm/39125/39125_service-manual_2540048010.webp)
Freeze Control Installation
579, 590 & 595 Series:
a. Snap freeze control into place on return bend located
at left side of evaporator coil as follows:
1) Locate “D” shaped notch in flange of evaporator
coil.
2) Place the horseshoe end of freeze control through
this notch and snap onto coil return bend. When
positioned correctly, control wires will be 90° to di-
rection of coil fin surface. See FIG. A20
Note:
Freeze control is not used on heat pump coils. Some
will have the “D” slot in the coil header.
Section A - Installation, cont’d.
FIG. A19
Freeze Control with wires.
Coil
Return
Bend
Do
kdkd
mfmf
Remove
Hang
Tag
600 SERIES
579, 590 & 595 SERIES
FIG. A21
FIG. A20
Mount the Freeze Control on left side
of coil, with wires to the right side
Install Freeze Control with wires as shown
Freeze Control Installation
600 Series:
a. Snap the freeze control into place on return end lo-
cated at right side of evaporator coil as follows:
1) Locate vertical return bend at lower right of evapo-
rator coil.
2) Place the horseshoe end of freeze control onto this
coil return bend and snap into place. When posi-
tioned correctly, control wires will be 90° to direc-
tion of coil fin surface. See FIG. A21.
Note:
Freeze control is not used on heat pump coils, some
8
A6a. Roof Top Units
Manual
Compliments
of
Northwest
RV
Supply
Printed
From
http://www.nwrvsupply.com