65
Section D - Configuration, cont’d.
One Dual Basement Air Conditioner Plus One Gas Furnace
To configure one dual basement air conditioner plus one
gas furnace, the STAGE Dip switch on AC power module
for Circuit 2 must be turned to ON. All other Dip switches
are OFF on both AC power module board. 115V AC (Cir-
cuit 1 and Circuit 2) are connected properly to CIR 1 and
CIR 2 terminal blocks; 12V DC, two thermostat wires from
furnace and cable communications lines are properly con-
nected to Circuit 1 AC power module board in the electrical
box.
Note:
If a remote sensor is used, it must be plugged into
the P4 (white) connector.
Improper connections can cause component
damage.
FIG. D19
FIG. D21
FIG. D20
DUAL BASEMENT
AIR
115V AC
CIRCUIT 2
115V AC
CIRCUIT 1
Typical installation for one com-
fort zone with dual basement air
and one furnace. Comfort control
may serve as a roomtemperature
sensor, or a remote sensor may
be used.